Mitel Rack PDM Charger Installation And Operation Manual page 10

Table of Contents

Advertisement

Rack PDM Charger
Installation and Operation Manual
IEC C13 connector.
For the Rack PDM Charger, connect the communication cable when required.
Installation Test
1
Connect the mains power supply cord to the wall socket.
2
The LED on the front of the charger should light up.
NOTE: The LED is disabled on the Rack PDM Charger and will not light up. Put a
handset into a charging slot and check if the handset LED lights up.
Power Supply by Fixed Connection
NOTE: If the Rack PDM Charger shall be connected with a fixed connection, the AC
connection must be done by a authorized electrician.
TIP: It is possible to use any of the two AC terminal blocks for AC input. Consequently,
the unused terminal block may be used to connect the next Rack PDM Charger or
battery pack charger.
The Power Supply module connects to 100-240VAC/0.7A 50/60 Hz. When working
with the units the mains power supply cable must always be disconnected. The safety
covers must be mounted on top of the power supply terminal blocks to prevent
hazardous situations, like electric chock.
21/1531-ANF 901 43 F 2017-04-25