Communication Cable Connection - Mitel Rack PDM Charger Installation And Operation Manual

Table of Contents

Advertisement

Rack PDM Charger
Installation and Operation Manual
Figure 10. The mains power supply connection.
8
Mount the safety cover and fasten it with one screw.
9
Secure the mains power supply cable with two screws (2), which are provided in
the parts bag, see
10
Replace the top cover, see
11
Fasten the power cord to the wall depending on local regulations.
12
If more Rack PDM Chargers shall be connected, repeat the above steps 1-12 for
the next unit.
Installation Test
1
When the fixed installation is completed, apply AC power by switching on the
disconnect device.
2
The LED on the front of each charger should light up.
NOTE: The LED is disabled on the Rack PDM Charger and will not light up. Put a
handset into a charging slot and check if the handset LED lights up.

2.1.5 COMMUNICATION CABLE CONNECTION

NOTE: This section is applicable for the Rack PDM Charger only.
The communication cable connections are situated under the top cover of the Rack
PDM Charger.
Figure 11. Communication connections inside the Rack PDM Charger.
21/1531-ANF 901 43 F 2017-04-25
figure
9.
figure 7
on page 11.
14