Mitel Rack PDM Charger Installation And Operation Manual page 17

Table of Contents

Advertisement

Rack PDM Charger
Installation and Operation Manual
The following parameters exist for the Rack PDM Charger and can be changed via the
WinPDM/CPDM3/WSM3.
Parameter
Ethernet Bit rate
Ethernet connector
Ethernet duplex
DHCP Enabled
Charger IP address
Subnet mask
Default gateway IP address
DNS IP address
Charger IP port
Service Discovery Enabled
Service Discovery Domain
DH IP address (one DH only)
DH IP port
a. Currently only "auto" setting is available.
Follow these instructions to set the Charger Rack parameters:
NOTE: It may be necessary to import the parameter definitions file that is included in
the software package. The package is provided by your supplier. The PDM/
Device Manager used may differ from the version that is described here.
1
Check that the Charger Rack is connected to the PDM/Device Manager.
2
In PDM or the Device Manager, click on the Numbers tab.
3
Select the Charger Rack device that you want to change parameters for.
4
In the Number menu, click "Edit...". The Edit parameters window opens.
5
Edit the parameters you want to edit.
6
Click "OK".
21/1531-ANF 901 43 F 2017-04-25
Description
a
auto (default)
1
auto (default)
1
auto (default)
Yes (default), No
192.168.0.101 (default)
255.255.255.0 (default)
192.168.0.1 (default)
192.168.0.2 (default)
12346 (default)
Yes (default), No
Name of domain
192.168.0.3 (default)
10147 (default)
17