When the scale is at zero the weight is not printed, only the number of items and total are printed.  
 
If the scale is set for continuous output (not approved models) the weight only is printed followed 
by 2 blank lines.  And example of continuous output is shown below. 
G R O S S , N E T ± _ _ _ _ _ 1 2 3 . 4 5 _ g _ <cr> <lf>
<cr> <lf>                                                                                                  
<cr> <lf>
22 Characters, ST for stable/US for unstable   followed by GROSS for Gross Weight/ NET for Net Weight and then a minus sign for negative weight, or a 
space for positive weight.   
 
Format 2 Output:
   
The output will be the same value as is on the display.   If parts counting, it will be the count, if 
weighing it is only the weight.  
An example output is : 
± _ _ _ _ _ _ 1 2 3 . 4 5 _ g _ <cr> <lf>
Parts Counting example: 
± _ _ _ _ _ _ _ _ _ 1 2 5 P C S <cr> <lf>
 
16 Characters, Begins with the sign,  a minus sign for negative weight, or a space for positive weight. 
 
 
For all examples if the weighing unit is one letter (i.e. grams=g)  the 2
used with a space before and after.  If it is 2 letters long, the 1st and second position is used with a 
space after the second letter, (i.e.  0.12345lb__ )  or if it is 3 letters long all 3 positions are used, 
(i.e  123.45dwt). 
  
Input command format:  
 
The scale can be controlled with the following commands. The commands must be 
sent in upper case letters, i.e. "T" not "t".  
 
T<cr><lf> 
Tares the scale to display the net weight. This is the same as pressing [‐>0/T<‐]
key. 
Z<cr><If> 
Sets the zero point for all subsequent weighing. Display shows zero. 
T5.345<cr><if> 
Would be same as entering a preset tare value of 5.345 from  keypad 
P<cr><lf> 
Prints  the  results  to  a  PC  or  printer  using  the  optional  RS‐232  interface.  It  also 
 
adds the value to the accumulation memory if the accumulation function is not 
set to automatic.  
 