Specifications - OPTEX FA CD5 Series Instruction Manual

Sensor head, displacement sensor cd5 series, laser type
Hide thumbs Also See for CD5 Series:
Table of Contents

Advertisement

Specifications

Model No.
Optical method
Measuring range
Light source
Laser
Class
Spot size *1
Light receiving
element
Linearity
Resolution *2
Sampling period *3
Temperature drift *4 ±0.01% F.S. / ℃
Supply voltage
Indicator
Protection
category
Operating
temperature
Operating humidity
Ambient light
Vibration
resistance
Material
Cable extension
Weight
<Measurement condition>
Unless otherwise designated, measurement condition is as follows. Using special controller/ operating temperature,
(depending on models)/ 256 times in average/ center/ standard testing object (specular reflection: evaporated alumin
*1 : Defined with center strength 1/e
*2 : 4096 times in average. Other conditions are same as the above condition.
*3 : Default setting of sampling period is as follows.
*4 : The typical value in the above condition.
8
SENSOR HEAD-MANUAL-E.indd 8
CD5-L25
Specular reflection
Center
25mm
±1mm
Wavelength 650nm /
Maximum output 390μW
IEC/JIS
CLASS 1
FDA
Appx.25x35μm
±0.08% F.S.
0.02μm
-10 to +50℃ (Free from condensation or icing) / For storage : -20 to +60℃
Sensor Head housing : Diecast Aluminum Cover of Emitting/receiving part : Glass
CD5-□□25 ~ □150 :100μs
CD5-W350 ~ W2000 :800μs
Displacement sensor
Ramco Innovations
CD5-LW25
CD5-30
Red Laser Diode
Wavelength 650nm /
Maximum output 1mW
Class Ⅱ
Appx.100x700μm Appx.30x100μm Appx.260x1,000μm
Linear image sensor
±0.08% F.S.
±0.05% F.S. / ℃
Supplied from special controller
Laser emission indicator : Green (ON during laser emission)
Distance indicator : Orange (Lights around center)
Distance indicator : Red (Lights at the near side)
Distance indicator : Green (Lights at the far side)
Distance indicator : Alternative Red/ Green(Lights alternatively outside the range)
IP67 (Including connecting part)
35% to 85%RH / For storage : 35% to 85%RH
Max. 3,000lx (Surface illuminance, Incandescent lamp)
10 to 55Hz Double amplitude 1.5mm 2 h per XYZ axes
Up to 50 m using an optional extension cable (unbundled)
Appx. 250 g (Including cable)
2
(13.5%) at the center. There may be leak light other than the specified spot size. The sens
800-280-6933 www.optex-ramco.com
CD5-W30
CD5-85
30mm
±5mm
Wavelength 658nm /
Wavelength 650nm /
Maximum output 1mW
Maximum output 1mW
Appx.70x290μm
±0.08% F.S.
0.2μm
100/200/400/800/1600/3200μs Setup to be done
CD5-W85
85mm
±20mm
Wavelength 658nm /
Maximum output 1mW
CL
Appx.260x1,200μm
±0.0
1μm
±0.01%
13.12.17 4:41:11 PM

Advertisement