3. Specifications
Type
Standard
Middle range
Model
CVS4
-N23W-R
-N24W-R
1)
Angle of view
Focal distance
50+/-6 mm
65 to 85 mm
38×19 to
Field of view (H×V)
30×15 mm
48×24 mm
OFF
1.1 to 12 mm 2.1 to 19 mm
Character
ON
2.2 to 24 mm 4.2 to 38 mm 1.5 to 16 mm 5.6 to 62 mm
height
(Each mode
FAST
2.2 to 12 mm 4.2 to 19 mm 1.5 to 8.2 mm
of "Wide")
FST2
Light
source
Lighting
Brightness
Approx.70 cd
Lifetime
(In room temperature and humidity. Brightness level down by 1/2 of the initial level)
Image sensor
330,000 pixels, CMOS monochrome image sensor
Supply voltage
Current consumption
Resolution
Response time
20 characters of the date in 2 rows Approx. 23 to 48 ms ("Rotate" 0 to +/-10°)
NPN Open collector output:x2, max.100 mA, Residual voltage 1.0 V or less,
Output signal
Input signal
Bank selection, String addition, External teaching, Synchronism, Pulse
12 ms (max): Bank selection
Input filter time
48 μs (turn on, max), 450 μs (turn off): Synchronism, Pulse train input
Operating temp./
humidity
Strage temp./humidity
10 to 55 Hz, Amplitude1.5 mm, 2 hours on XYZ each axis /
Vibration/Shock
EMC Directive (2014/30/EU), EU Battery Directive (2006/66/EC),
Applicable regulation
Applicable standard
Material
Case: ABS, LCD & LED Lens: Acrylic (LED Lens for -N21W-R & -N40W-R: PC)
Protection class
Weight
Recognized number of
characters, rows
Recognized number of
characters per a row
Recognized number of
dates, times, and
strings
User-defined dictionary
56 characters (Registered by NG Log or transferred from PC
Month: 1 chr., Date: 2 chr., Hour: 1 chr., Minute: 1 chr.
Date and time in letters
Converting to the above-mentioned alphabetical and numeric characters is available.
Built-in clock accuracy
Monthly difference: -45 sec to + 1 min 15 sec (Typical value)
Built-in clock
Primary battery: 5 years with the power OFF (Typical value)
Backup
Supercapacitor: 7.8 years (Typical value with 3 days of backup time)
Communication
1) For the PNP output type, the "N" after the hyphen is changed to a "P." ex.) CVS4-N23W-R → CVS4-P23W-R
There are other special models in addition to the one shown above. For details, contact Optex FA.
2) The minimum detectable character height depends on the distance.
CVS4-N24W-R: 2.1 mm (at 65 mm) to 2.7 mm (at 85 mm)
CVS4-N20W-R: 2.8 mm (at 90 mm) to 4.2 mm (at 150 mm)
CVS4-N40W-R: 2.8 mm (at 40 mm) to 5.9 mm (at 100 mm)
3) Approximately 100 ms is required from the point where the bank is switched to the point where the next image can be captured.
4) To connect this device to a PC, the optional PC I/F cable CVS-C2C (sold separately) is required. You can also download the setup
software (see P.14) free of charge from the Optex FA website, "www.optex-fa.com."
4. I/O Circuit Diagram and Wiring
[I/O Circuit Diagram (NPN Type)]
Photo coupler
Internal
7.5 kΩ
circuit
15 kΩ
Protection diode
Internal
circuit
[Wiring example for NPN output]
Typical example to connect Synchronous sensor, Rotary encoder, Reject mechanics and Bank-selection
switch.
Brn
Blu
Ora/Blk
Yel/Blk
Pnk
Pur
Blk
Red/Blk
Brn
Blu
Blk
Brn
Blu
Blk
* When capturing images of moving objects, timing input from a synchronous sensor is required.
For small
Long range
Wide
characters
-N21W-R
-N20W-R
-N40W-R
20°
40°
35+/-4 mm
90 to 150 mm 40 to 100 mm
53×25 to
53×25 to
21×10 mm
79×38 mm
115×53 mm
0.75 to 8.2 mm 2.8 to 31 mm
2.8 to 43 mm
2)
2)
N/A
2)
5.6 to 31 mm
5.6 to 43 mm
2)
12 White LEDs
Approx.35 cd Approx.70 cd Approx.54 cd Approx.70 cd
Approx. 100,000 hours
12 to 24 VDC +/-10%
Max.140 mA / 24 VDC
512×244
OK/NG output, External light control
, String addition, External teaching input,
3)
0 to 40°C (No condensation), 35 to 85%/RH
'-20 to +70°C, 25 to 95%/RH
50 G (500 m/s
) 3 times on XYZ each axis
2
RoHS Directive (2011/65/EU, MIIT Order No.32)
EN61000-6-2, EN61000-6-4
IEC 60529: IP67
Approx. 200 g (Including cable)
60 characters (All rows) / 6 rows
30 characters per row
4 in total: Each 2 for the date and the time,
below 4 for the string (total 22 characters)
(Transferred from PC)
4)
RS-232C (TTL Level) 4,800 to 115,200 bps
4)
(For details on PNP output types, see the appendix.)
Brn: 12 to 24 VDC
Ora/Blk: Bank selection 0 input / Pulse train input
Yel/Blk: Bank selection 1 input / String +input
Pnk: Bank selection 2 input / External teaching input
Pur: Bank selection 3 input / Synchronizing input
Red/Blk: NG output / Light control output / Input
(Input: Bank selection 0 to 3 / Teach /
String+)
Blk: OK output / Light control output
Blu: 0 V
AC
AC
+
−
+
−
+
−
C
1
2
5. Dimensions
42
Standard,
Vertical
-N23RW-R
20°
50+/-6 mm
15×30 mm
1.1 to 12 mm
2)
2.2 to 24 mm
2.2 to 12 mm
2)
244×512
13.2
15.5
6. Part Names and Functions
Keypad
)
4)
Power supply, I/O
cable
7. Options and External Lighting Devices
[Options that can be connected to the CVS4]
Model
Remote monitor
CVS-M1-R
PC I/F cable
CVS-C2C
Video cable
CVS-CN
PC I/F cable + video
cable
CVS-C2P
PC I/F cable + I/F cable
for video out
CVS-C2Y
Extension cable for
remote monitor (3 m)
CVS-C3S
[External lighting]
Model
External bar lighting, white light, 50 mm
wide
OPB-5015W2-B
External bar lighting, white light, 100 mm
wide
OPB-10015W2-B
LED lighting controller
OPPD-15
Lighting power supply
OPP-10-H (10 W)
Lighting power supply
OPP-30-H (30 W)
Bar lighting mounting bracket
CVS-OPDB-2000
Bar lighting mounting bracket
CVS-OPDB-3040
Bar lighting mounting bracket
CVS-OPDB-6080
We can prepare the optimum lighting units to match your applications and objects. Contact Optex FA for
details.
2
33.8
4.2
4
95
87
2-ø4.3
Tightening torque:
0.8 N·m or less
11
External connector
(not available on the remote monitor)
You can download CAD data from the
11.2
Optex FA website.
http://www.optex-fa.com
LCD monitor
Mounting holes
The hole to mount the sensor.
Screws of M4 X 50 mm or larger are recommended.
(4.3 in diameter, pitch 87.0 mm, depth 42.0 mm)
The camera and the lighting are at the rear side.
External connector
Connects external options as remote monitor, external lighting, and/or cables.
Application
This is a monitor unit equipped with a remote control function for the CVS series. Connect
this unit when viewing the judgment results at a distance from the objects. You can also
perform teaching and set the parameters of this unit in the same way as the CVS4 series.
You can use this cable to connect to a PC in order to read and save data. Download the
communication software from the Optex FA website (http://www.optex-fa.com).
This cable is equipped with a pin plug for connecting to the video input terminal of a NTSC
TV or similar device in order to view the images captured with the CVS4.
This cable is equipped with a pin plug for communicating with a PC and, at the same time,
viewing the images captured with the CVS on a NTSC TV or similar device.
This cable can be used to communicate with a PC and, at the same time, view the captured
screens on the remote monitor CVS-M1-R. (You cannot perform operations from the
CVS-M1-R. You can only view the screen.)
Use this to extend the dedicated cables and the cable of the remote monitor CVS-M1-R.
You can use up to four extension cables (for a total length of 15 m).
Use this option when the built-in lighting causes glare.
The OPPD-15 or OPP-10-H (10 W) will be required (sold separately).
Use this option when the built-in lighting causes glare.
The OPPD-15 or OPP-30-H (30 W) will be required (sold separately).
This is the controller for the OPB-5015W2-B and OPB-10015W2-B.
Supply voltage of 24 VDC and 1 lighting output channel.
This is the 100 VAC power supply for the OPB-5015W2-B. It has 2 lighting
output channels.
This is the 100 VAC power supply for the OPB-10015W2-B. It has 2
lighting output channels.
This mounting bracket is used to install the CVS and the OPB-5015W2-B
vertically.
(You can use two mounting brackets to install two OPB-5015W2-B
lighting units.)
This mounting bracket is used to install the CVS and the OPB-5015W2-B
or OPB-10015W2-B horizontally. (You can use two mounting brackets to
install two OPB-10015W2-B lighting units.)
You can make horizontal adjustments over a range of 30 mm and height
adjustments over a range of 40 mm.
This mounting bracket is used to install the CVS and the OPB-5015W2-B
or OPB-10015W2-B horizontally. (You can use two mounting brackets to
install two OPB-10015W2-B lighting units.)
You can make horizontal adjustments over a range of 60 mm and height
adjustments over a range of 80 mm.
21
28.2
Main unit: Cable length: 2 m
Remote monitor: Cable length: 3 m
ø5 mm, 8 cores × 0.08 mm
2
Heat-resistant soft vinyl
Unit: mm
Application
Need help?
Do you have a question about the CVS4-*R Series and is the answer not in the manual?