2.6.2 Ignition Control Wiring
To activate ignition control, you need to provide IGN signal via the 3-pin pluggable
terminal block locates in the back panel. Please find below the general wiring
configuration.
Pin No.
1
2
3
For testing purpose, you can refer to the picture blow to simulate ignition signal
input controlled by a latching switch.
Note :
1. DC power source and IGN share the same ground.
2. EVS-2000 supports 9V to 50V wide range DC power input in ATX/AT mode. In
Ignition mode, the input voltage is fixed to 12V/24V for car battery scenario.
3. For proper ignition control, the power button setting should be "Power Down"
mode.
©Vecow EVS-2000 User Manual
Definition
Ignition (IGN)
SW+
SW-
V+
In Windows for
example, you need
to set "When I press
the power button" to
Shut down.
GETTING TO KNOW YOUR EVS-2000
IGN