BINMASTER CNCR-110 Operating Instructions Manual

Radar sensor for continuous level measurement

Advertisement

Quick Links

Operating Instructions
Radar sensor for continuous level measurement
CNCR-110
Two-wire 4- 20 mA
Document ID: 925-0390 Rev B
CNCR-110 • Two-wire 4-20
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CNCR-110 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BINMASTER CNCR-110

  • Page 1 Operating Instructions Radar sensor for continuous level measurement CNCR-110 Two-wire 4- 20 mA Document ID: 925-0390 Rev B CNCR-110 • Two-wire 4-20...
  • Page 2: Table Of Contents

    8.1 Maintenance ........................14 8.2 Status messages ......................14 Removal ..........................16 9.1 Disposal ......................... 16 Certificates and approvals ....................17 10.1 Radio licenses......................17 Supplement .......................... 17 11.1 Technical data ......................17 11.2 Dimensions........................19 CNCR-110 • Two-wire 4-20...
  • Page 3: About This Document

    Required personal protective equipment must always be worn when working on or with the device. 2.2 Appropriate use CNCR-110 is a sensor for continuous level measurement. Operational reliability is ensured only if the instrument is properly used according to the specifications in the operating instructions. CNCR-110 • Two-wire 4-20...
  • Page 4: Warning About Incorrect Use

    These instructions are attached as documents to each instrument with Ex approval and are part of the operating instructions. 3 Product Description 3.1 Configuration Constituent parts Fig. 1: Components of CNCR-110 1 Process fitting 3 Electronics housing 4 Mounting thread 5 Locking nut 6 Connection cable CNCR-110 •...
  • Page 5: Principle Of Operation

    3.2 Principle of operation CNCR-110 is a radar sensor for continuous level measurement. It is suitable for liquids and solids in practically all industries. The instrument emits a continuous, frequency-modulated radar signal from its antenna. The emitted signal is reflected by the material and received by the antenna as an echo with a modified frequency. The frequency change is proportional to the distance to the material. 3.3 Adjustment Devices with integrated Bluetooth module can be adjusted wirelessly via software adjustment tools: •...
  • Page 6: Mounting

    The narrow portion of the radar signal is in the middle of the printed label on the instrument. This should be pointed towards the center of the vessel or any obstacle that may cause and unwanted reflections to minimize false echos, for example, the sidewall or vessel structure. CNCR-110 • Two-wire 4-20...
  • Page 7 Fig. 5: Mounting the radar sensor on round vessel tops In vessels with cone bottoms, the sensor can be mounted in the center of the vessel to measure material down to the outlet. CNCR-110 • Two-wire 4-20...
  • Page 8 When using a threaded coupling, the antenna end should protrude at least 5 mm (0.2 in) out of the coupling. If the reflective properties of the material are good, you can mount the CNCR-110 on sockets or stand pipes longer than the antenna. The pipe end should be smooth, burr-free and the end rounded. CNCR-110 • Two-wire 4-20...
  • Page 9 The sensor should be mounted in a location where the radar signal is not interfered with by structure, such as ladders, braces or fill stream. Make sure when planning the installation there is a clear, unobstructed view to the material to be measured. After installation a false signal suppression should be carried out to minimize any reflections from the mount or nearby structure. CNCR-110 • Two-wire 4-20...
  • Page 10: Connecting To Power Supply

    The device is supplied with a fixed cable. If an extension is required, a standard two-wire cable can be used. 5.2 Wiring Plan Fig. 9: Wire assignment in permanently connected connection cable Wire color Function Polarity Brown Voltage supply, signal output Plus (+) 24 VDC Blue Voltage supply, signal output Minus (-) CNCR-110 • Two-wire 4-20...
  • Page 11: Setup With Smartphone/Tablet (Bluetooth)

    • Operating system: Android 5.1 or newer • Bluetooth 4.0 LE or newer Download the Wireless Device Configurator app from the “Apple App Store” or “Google Play Store” to your smartphone or tablet. To enable the Bluetooth software enter the BinMaster company ID code BMYQXZ. 6.2 Connecting Start the adjustment app and select the function “Setup”. The smartphone/tablet searches auto- matically for Bluetooth-capable instruments in the area.
  • Page 12: Parameter Adjustment

    Close the app to terminate connection. Note: If the CNCR fails to connect to the Wireless Device Configuration App (WDCA) via Bluetooth, close the (WDCA), power cycle the CNCR and attempt to reconnect. If further action is required, power cycle the Bluetooth on your device, and repeat the steps above. CNCR-110 • Two-wire 4-20...
  • Page 13: Menu Overview

    Linearization type Linear Scaling Scaling size 0% correspond to 0 l Scaling unit 100% correspond Scaling format to 100 l Display Menu language English Displayed value Distance Backlight Access protection Bluetooth access code Parameter Protection Deactivated CNCR-110 • Two-wire 4-20...
  • Page 14: Diagnostics And Servicing

    If necessary, clean the antenna system periodically. 8.2 Status messages The status messages are divided into the following categories: • Failure • Function check • Out of specification • Maintenance required CNCR-110 • Two-wire 4-20...
  • Page 15 Program sequence of the Device restarts automatically Measurement function measuring function disturbed disturbed Function check Code Text message Cause Rectification C700 A simulation is active Finish simulation Simulation active Wait for the automatic end after 60 mins. CNCR-110 • Two-wire 4-20...
  • Page 16: Removal

    Software update M510 No communication with the sensor 9 Removal 9.1 Disposal The device is made of recyclable materials that can be disposed of by specialty recycling companies. Observe the applicable local regulations for proper disposal. CNCR-110 • Two-wire 4-20...
  • Page 17: Certificates And Approvals

    7 Nm (5.163 lbf ft) Measurement Range Measurement range The measurement range is the distance between the antenna face of the sensor and the material surface. The antenna face is also the reference plane for the measurement. CNCR-110 • Two-wire 4-20...
  • Page 18 -40 to +80 °C (-40 to +176 °F) Process conditions For the process conditions, please also note the specifications on the printed label. The lowest value (amount) always applies. Process temperature -40 to +60 °C (-40 to +140 °F) Process pressure -1 to 3 bar (-100 to 200 kPa/-14.5 to 43.51 psig) CNCR-110 • Two-wire 4-20...
  • Page 19: Dimensions

    IP66/IP68 (3 bar) acc. to IEC 60529, Type 4P acc. to UL 50 Altitude above sea level 5000 m (16404 ft) Protection class Pollution degre 11.2 Dimensions CNCR-110 Fig. 13: Dimensions CNCR-110 1 Thread G1½ 2 Thread 1½ NPT 3 Thread R1½ CNCR-110 • Two-wire 4-20...
  • Page 20 Subject to change without prior notice. BinMaster Phone: 402-434-9102 7201 N 98th St. Fax: 402-434-9133 Lincoln NE 68507 E-mail: info@binmaster.com www.binmaster.com CNCR-110 • Two-wire 4-20...

Table of Contents