Yes
No
Go to "Starting Problem Analysis" in topic 1.2.
7.
Install the front cover (see "Front Cover Removal or Installation
Procedure" in topic 4.3).
8.
The 3514 is operational and ready to be used by the system.
End of procedure.
9.
The 3514 is performing the switch-on power sequence:
Note:
Normal switch-on power sequence is completed in 3 minutes and
*000 is displayed on the Data display.
Has the Power switch in the 3514 been set to the On position for more
than 3 minutes?
Yes
No
Go to step 10.
Exchange the part (indicated in the table with this step) to correct
the problem.
For the exchange procedure, see "Controller Card" in
topic 4.5.8.
CAUTION:
The controller card contains a lithium battery.
explosion, do not burn, exchange, or charge the battery.
controller card as instructed by local regulations for lithium
batteries.
(RSFTC228)
+--------------------------------------------------------------------+
¦ Location
+----------------------+----------------------+----------------------¦
¦
¦ D
+----------------------+----------------------+----------------------¦
¦ 9
+----------------------+----------------------+----------------------¦
¦ F
+----------------------+----------------------+----------------------¦
¦ A-C
+--------------------------------------------------------------------¦
¦ Note:
See the "Failing Item Table" in topic 3.3 for the correct
¦ part number for a specific FRU part.
+--------------------------------------------------------------------+
End of procedure.
10. A series of Bxxx characters are displayed.
B000, or BBA0 should be displayed.
After 3 minutes, is *000, B000, or BBA0 displayed on the Data display?
Yes
No
Return to step 1.
11. From your computer system, run the diagnostic test programs for the
3514/A Array Adapter.
for instructions on running diagnostics.)
Did the test programs run without error?
Yes
No
Go to "Starting Problem Analysis" in topic 1.2.
12. Is *000 displayed on the Data display?
Yes
No
Go to "Starting Problem Analysis" in topic 1.2.
3514 Service Information
Analyzing No-Response Problems
¦ Probable Cause
¦
¦ 90%
¦ 8%
¦ 1%
¦ 1%
After 3 minutes, *000,
(See the 3514 Quick Reference Manual, SA21-9613
¦ Copyright IBM Corp. 1992, 1993
1.4 - 2
To avoid possible
Discard the
¦ Description
¦ Controller card (see ¦
¦ caution notice)
¦ Control panel
¦ Connector panel
¦ Power module
¦
¦
¦
¦
¦
¦
¦

Advertisement