4.5.17 Verifying a Repair
Use the following procedure to verify a 3514 repair:
1.
Did you exchange a power module?
Yes
No
Go to step 3.
2.
Locate the power module that has been exchanged (A, B, or C) and go to
step 17.
3.
Did you exchange a FRU because of a URC of C9Dx or C9xD?
No
Yes
Go to step 12.
4.
Did you exchange a FRU because of a URC of C9xx?
Yes
No
Go to step 6.
5.
Locate the power module that reported the error and go to step 17.
The third character of the URC contains the location (A, B, or C) of
the power module.
6.
Did you exchange a FRU because of one of the following URCs?
5xxx
6xxx
7xxx
8xxx
9xxx
Dxxx
Exxx
Yes
No
Go to step 8.
7.
Locate the disk drive that reported the error and go to step 25.
third character of the URC contains the slot number (1-8) of the disk
drive.
8.
Did you come to this procedure from a problem recovery procedure in
this manual?
Yes
No
Go to step 12.
9.
Set the 3514 Power switch to the On position.
10. After 3 minutes, the power-up sequence should be complete.
Is *000 or B000 displayed?
Yes
No
The exchange procedure was not successful.
recovery procedure that sent you to this procedure.
11. The exchange procedure was successful.
procedure that sent you to this procedure.
End of verifying a repair.
12. Set the 3514 Power switch to the On position.
13. After 3 minutes, is *000, B000, or BBA0 displayed on the Data display?
Yes
No
Go to "Starting Problem Analysis" in topic 1.2.
3514 Service Information
Verifying a Repair
Return to the problem
Return to the problem recovery
¦ Copyright IBM Corp. 1992, 1993
4.5.17 - 1