IBM PS/2 3514 Service Information page 144

Advertisement

3.5.18.1 URC 5tpx
t=1, 3, or 6
p=1 through 8
x=0, 1, 2, 3, 7, 9, A, B or F
An error has occurred while rebuilding data:
To correct this error, perform the following:
1.
To prevent data loss, the disk drive in the slot indicated by the
third position of the URC must be returned to the 3514 configuration.
2.
Using the control panel, enter the following sequence of commands:
3.
Set the 3514 offline:
9 1 7 0
PICTURE 211
A display of 90FF indicates that the 3514 is offline.
4.
This error may have been caused by electrical noise or an unseated
cable.
Attempt to reset this disk drive by performing the procedure
"Reset Disk Drive" in topic 4.5.7.
5.
Did the procedure "Reset Disk Drive" complete without an error?
No
Yes
Go to step 20.
6.
Use the URC error log to find the URC that occurred during the
exchange command in step 4.
the error log entry.
Error Log" in topic 2.6.)
7.
Is the rightmost character of the URC (the fourth character in the
error log entry) a 0 or 3?
No
Yes
Go to step 11.
8.
Exchange the controller card using the exchange procedure "Controller
Card" in topic 4.5.8. Then return to step 9 in topic 3.5.8.1 in this
procedure.
CAUTION:
The controller card contains a lithium battery.
explosion, do not burn, exchange, or charge the battery.
controller card as instructed by local regulations for lithium
batteries.
(RSFTC228)
+--------------------------------------------------------------------+
¦
Location
+----------------------+---------------------------------------------¦
¦ D
+--------------------------------------------------------------------¦
¦ Note:
See the "Failing Item Table" in topic 3.3 for the correct
¦ part number for a specific FRU part.
+--------------------------------------------------------------------+
9.
Set the Power switch to the On position.
After 3 minutes, is 3514CE27 or the same URC that initiated this
repair action (35145tpx) displayed on the 3514 control panel?
Yes
No
End of procedure.
10. Set the 3514 offline:
9 1 7 0
PICTURE 212
A display of 90FF indicates that the 3514 is offline.
11. Perform the exchange procedure "Disk Drive Logic Card" in topic 4.5.2.
Then return to the next step in this procedure.
3514 Service Information
URC 5tpx
Customer data was damaged.
Then, continue with the next step.
The URC is the 4 leftmost characters in
(See "Using the 3514 Unit Reference Code (URC)
¦
Description
¦ Controller card (see Caution notice)
¦ Copyright IBM Corp. 1992, 1993
3.5.18.1 - 1