9 1 7 0
PICTURE 100
A display of 90FF indicates that the 3514 is offline.
27. Exchange the disk drives using the exchange procedure "Disk Drive" in
topic 4.5.1.
28. Using the control panel, set the 3514 online by entering the following
sequence:
9 0 7 9
PICTURE 101
End of procedure.
29. Insert each disk drive, except the one which could not be found, in
the slot recorded in step 4.
Attach the disk drive power and data cables.
Warning:
If these disk drives have been installed in another device
or system, data corruption may be present.
topic 3.5.6.1 if you are not sure about the data integrity of the disk
drives.
Note:
Ensure that each disk drive is connected to the correct power
cable and signal cable. Also, ensure that the address jumper is
installed in the position shown and is only installed on disk drives
in odd-numbered slots (1, 3, 5, or 7).
PICTURE 102
30. Insert a new disk drive in the slot for which the disk drive could not
be found.
Attach the disk drive power and data cables.
31. Set the Power switch to the On position.
32. After 3 minutes, a URC should be displayed on the 3514 control panel?
Is 35147xx7 or 35148xx7 displayed on the 3514 control panel?
Yes
No
Go to "Starting Problem Analysis" in topic 1.2.
33. Install the new disk drive.
with the slot number of the new disk drive.
This will make the new disk drive part of the 3514 configuration and
will rebuild the data on it.
End of procedure.
3514 Service Information
URC CE27
Go to step 24 in
Use "Reset Disk Drive" in topic 4.5.7
¦ Copyright IBM Corp. 1992, 1993