21 : the key entered does not correspond to the system: the services are open for a limited
time.
24 : the software key entered does not correspond to system software version (invalid serial
number): the services are open for a limited time.
26 : a software key with too old an edition has been entered: the services are open for a
limited time.
32 : the services were closed; entering a valid key causes the services to open.
35 : the services were closed; the new key entered has a valid serial number but a version
which does not correspond to the system: the services remain closed.
37 : the services were closed; the new key entered has a valid serial number but too old: the
services remain closed.
41 : the key version does not correspond to the system; the new key entered does not
correspond to the system (invalid serial number): the services are open for a limited time.
42 : the key version does not correspond to the system; a valid key was entered: the services
are open.
45 : the key version does not correspond to the system; the end of the limited time causes the
services to close.
46 : the key version does not correspond to the system; a new key with a valid serial number
but too old an edition has been entered: the services are open for a limited time.
52 : the services were closed; a valid key was entered: the services are open.
53 : the services were closed; the key entered does not correspond to the system: the services
remain closed.
57 : the services were closed; the key entered has a valid version but does not correspond to
the system (invalid serial number): the services remain closed.
61 : the system's edition is too old; the new key entered does not correspond to the system:
the services are open for a limited time.
62 : the system's edition is too old; a valid key was entered: the services are open.
64 : the edition of the system's key is too old; a new key with a valid edition, but an old version,
was entered: the services are open for a limited time.
67 : the system's key is too old; the end of limited time causes the services to close.
72 : the system's key is too old; the services were closed; the new key entered is valid: the
services are open.
73 : the system's edition is too old; the services were closed; the new key entered has a
problem with the serial number: the services remain closed.
75 : the system's key is too old; the services were closed; the new key entered has a valid
serial number, but a version which does not correspond to the system: the services remain
closed.
6.6
Management of two-color led on attendant station
The two-color LED on the attendant station flashes quickly (orange) in the following cases:
-
either of the 2 following T2 alarms(message 53):