Type Message
0
SYSTEM RESTART
1
DOWNLOAD INFORMATION
2
SWAP INFORMATION
Program change-over
3
LAUNCH OF DATA SAVING
Data Saving
4
DATA SAVING BACKUP OK
Location
Additional Information
INFO 0 = reason to restart
1 : MMC reset command
2 : reset due to hardware fault
3 : mail notify queue is full
4 to 5: reset following software
problem
6: reset due to an external applica-
tion to take into account new config-
uration
For example: push of new software
licenses by Web access, cold re-
set...
7 : reset following software license
problem (the values of the default
key are used)
11 : reset following software swap
or after restoration after swap
12 : too many one-way communica-
tions
13 : automatic restart programmed
by MMC
14 : timeout expiration
15 : no more inodes in notifqueue
55 : normal reset
CPU (80)
INFO 0 = information
1 : download started
2 : download finished
3 : download failure
INFO 1 = cause of failure
0 : download complete
9 : invalid date
11 : file transfer error
14 : download incomplete
CPU (80)
INFO 0 =1: swap complete; 2: data
saving error; 3: fault during swap
INFO 1 = type of swap: 0 : normal
with data saving; 1: normal without
data saving; 2: forced with data
saving
INFO 2 = acknowledgement: 0 : no
problem; 1: save KO; 2: restore KO;
3: save/restore KO
CPU (80)
CPU (80)
Action
29/62