Siemens MindConnect Nano Getting Started page 25

Getting connected to mindsphere
Hide thumbs Also See for MindConnect Nano:
Table of Contents

Advertisement

Name
Status
ORANGE
ORANGE
ORANGE
Blinking
GREEN
Blinking
USER LED ORANGE
Flashing
GREEN
ORANGE
RED
Blinking
You can find more information about LED errror codes in section Troubleshooting (Page 26).
Getting Connected to MindSphere
Getting Started, 05/2018
Description
NO CONNECTION TO PROXY
Network cable is missing or damaged
·
Ethernet port on MindConnect IoT2040 is damaged
·
"ipconfig" of MindConnect IoT2040 is incorrect
·
Firewall of MindConnect IoT2040 blocks
·
Your company's' router is damaged
·
Proxy is offline
·
No authentication on Proxy
·
Proxy configuration is invalid
·
NO CONNECTION TO CLOUD
Proxy is invalid
·
Server is offline
·
An addressed server cannot be accessed
·
Network problems of a provider
·
No authorization
·
CONNECTION TO CLOUD ESTABLISHED
LED light flashes green for a short time to indicate the onboarding process - otherwise is
orange
ONBOARDING IN PROGRESS
ONBOARDING FAILED
LED flashes red for a short time to indicate onboarding is falling
Possible reason:
Server error
·
OBT is no longer valid
·
For explanation of possible problems and respective solution, please refer to the chapter
"Troubleshooting".
ONBOARDED
NO CONNECTION TO DATASOURCE
Problem with network connection of your machine
·
Network cable is not plugged in or is damaged
·
Machine is offline
·
MindConnect IoT2040 IS LOSING DATA
MindConnect IoT2040 is offline and the data buffer is full
·
Slow data transfer
·
For explanation of possible problems and respective solution, please refer to the chapter
"Troubleshooting".
Mounting and installing MindConnect Elements
4.4 LED lights of MindConnect Elements
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mindconnect iot2040

Table of Contents