Scott PROFLOW FH22 Installation And Use Instructions Manual

Papr hood

Advertisement

Quick Links

INSTALLATION AND USE INSTRUCTIONS
SCOTT PROFLOW FH22 PAPR HOOD
INSTALLATION AND USE INSTRUCTIONS
SCOTT PROFLOW FH22 PAPR HOOD
(Shown with optional Breathing Tube Shroud)
WARNING
I
MPROPER USE OF THIS EQUIPMENT MAY RESULT IN SERIOUS INJURY OR DEATH. IMPROPER USE INCLUDES, BUT
IS NOT LIMITED TO, USE IN ATMOSPHERES CONTAINING UNKNOWN CONTAMINANTS AND/OR UNKNOWN CONCEN-
TRATIONS OF CONTAMINANTS, USE WITHOUT ADEQUATE TRAINING, DISREGARD OF THE WARNINGS AND
INSTRUCTIONS CONTAINED HEREIN AND FAILURE TO INSPECT AND MAINTAIN THIS EQUIPMENT.
THIS EQUIPMENT ALONE DOES NOT PROVIDE RESPIRATORY PROTECTION WITHOUT THE COMPLETE RESPIRA-
TOR. THE COMPLETE RESPIRATOR IS TO BE USED ONLY IN CONJUNCTION WITH AN ORGANIZED RESPIRATORY
PROTECTION PROGRAM WHICH COMPLIES WITH THE REQUIREMENTS OF A NATIONALLY RECOGNIZED STANDARD
SUCH AS OSHA SAFETY AND HEALTH STANDARD 29 CFR 1910 PARAGRAPH 134, AVAILABLE FROM THE US DEPART-
MENT OF LABOR, OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION.
THIS EQUIPMENT IS NOT INTENDED FOR USE IN ATMOSPHERES WHICH ARE, OR MAY BECOME, IMMEDIATELY DAN-
GEROUS TO LIFE OR HEALTH (IDLH), IN HIGH TEMPERATURE ENVIRONMENTS SUCH AS FIRES, OR IN ATMOSPHERES
WHERE THE IDENTITY AND/OR CONCENTRATION OF THE CONTAMINANT IS UNKNOWN.
THIS EQUIPMENT AS PART OF A COMPLETE RESPIRATOR MUST BE USED ONLY IN ATMOSPHERES FOR WHICH THE
PROPER FILTRATION MEDIA HAS BEEN CHOSEN TO BE EFFECTIVE AGAINST AND ONLY AT CONCENTRATIONS OF
CONTAMINANTS WHICH ARE KNOWN NOT TO BE IMMEDIATELY DANGEROUS TO LIFE AND HEALTH (NON-IDLH) AND
FROM WHICH A USER MAY ESCAPE WITHOUT THE USE OF THE RESPIRATOR.
THIS EQUIPMENT DOES NOT SUPPLY OXYGEN AND MUST NOT BE USED IN OXYGEN DEFICIENT ATMOSPHERES.
Copyright © 2008 SCOTT, All Rights Reserved
1
P/N 595141-01 Rev A 7/08

Advertisement

loading

Summary of Contents for Scott PROFLOW FH22

  • Page 1 CONTAMINANTS WHICH ARE KNOWN NOT TO BE IMMEDIATELY DANGEROUS TO LIFE AND HEALTH (NON-IDLH) AND FROM WHICH A USER MAY ESCAPE WITHOUT THE USE OF THE RESPIRATOR. THIS EQUIPMENT DOES NOT SUPPLY OXYGEN AND MUST NOT BE USED IN OXYGEN DEFICIENT ATMOSPHERES. Copyright © 2008 SCOTT, All Rights Reserved P/N 595141-01 Rev A 7/08...
  • Page 2: Installation And Use Instructions

    Hood. Air entering WHILE UNDER THE INFLUENCE OF the PROFLOW FH22 Hood is directed over the top of the head and down the DRUGS, ALCOHOL, OR ANY MEDICA- inner surface of the visor to prevent misting, then inhaled by the wearer.
  • Page 3 Consult a qualified industrial hygienist for advice on the use of the PROFLOW FH22 PAPR Hood in your work environment. Take into consideration that seams and closures often have shorter breakthrough times and higher chemical permeation rates than the fabric alone.
  • Page 4 PROFLOW FH22 Hood from service and tag for repair or replacement as required. Inspect as follows: 1. Inspect the PROFLOW FH22 Hood for any holes or tears in the fabric. 2. Verify that all seams and joints are secure and show no signs of weakening or breakdown.
  • Page 5: Installation

    BREATHING TUBE ATTACHMENT TO THE HOOD To remove or install a breathing tube on a PROFLOW FH22 Hood, proceed as follows: REMOVAL 1. Grasp the hose from the outside of the hood right where it enters the hood. 2. Turn the hood inside out to access the hose nut on the inside of the hood.
  • Page 6 THE BREATHING TUBE SHROUD A breathing tube shroud is available for the PROFLOW FH22 Hood made of the same material as the hood fabric. The breathing tube shroud is used to facilitate cleaning and/or decontamination of the breathing tube. ATTACH THE BREATHING TUBE SHROUD AS FOLLOWS: 1.
  • Page 7 REMOVE THE BREATHING TUBE SHROUD AS FOLLOWS: 1. The tie wraps are the removable type. On the lock end, press down on the lock release below the cut off end of the tie wrap while pulling the loop open. 2. If desired, the tie wraps may be cut off and replaced with new ones when the breathing tube shroud is replaced.
  • Page 8 R E S P I R ATO R AT TA C H E D TO I T. I M - 1. Examine the PROFLOW FH22 Hood to be certain it is complete and in P R O P E R U S E O F T H I S E Q U I P M E N T serviceable condition.
  • Page 9 8. Locate the breathing tube over the left shoulder while placing the head into the head band of the PROFLOW FH22 Hood. Fit the padded portion of the head band around the fore- WARNING head with the visor window POSITION THE BLOWER ASSEMBLY centered in front of the face.
  • Page 10: Termination Of Use

    Loosen the neck cord by pressing the black button inward as you slide the cord lock away from your chin. b) Roll up the PROFLOW FH22 Hood starting at the bottom rear and proceeding up the back of the neck. See FIGURE 10.
  • Page 11 HANDLE CONTAMINATED HOODS WITH nated object. CARE. DO NOT THROW AWAY CONTAMI- 3. The PROFLOW FH22 Hood is intended for a single use. Dispose of the NATED HOODS AS ORDINARY TRASH. DISPOSE OF CONTAMINATED HOODS IN used hood according to the procedures defined by your respiratory pro-...