2. How to Use ..........................10 2-1. Procedures to operation ........................10 3. Wiring ............................ 11 3-1. AC adapter type/ IZG10-□01, 02 ......................11 3-2. Power cable type/ IZG10-□03 ....................... 11 4. Function ..........................12 4-1. Name of parts ............................12 4-2.
Doc. no.IZ*-OMX0012 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) and other safety regulations.
Page 4
Doc. no.IZ*-OMX0012 Safety Instructions Caution The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary.
Page 5
Doc. no.IZ*-OMX0012 Selection Warning 1) This product is intended to eliminate static electricity from general factory automation equipment. If considering using the product for other applications (especially those indicated in (4) on page 3), please consult SMC beforehand. 2) Do not operate beyond the specifications. If the product is used outside of the specifications, it may cause malfunction, failure or damage to the product, leading to an electric shock, explosion or fire.
Page 6
Doc. no.IZ*-OMX0012 Handling Warning 1) Mount the designated nozzle to the product. 2) Confirm that the nozzle is not loose or does not have play before supplying compressed air. When the nozzle is loose, tighten it by hand until it does not rotate (guideline of the tightening torque by hand: 0.1 to 0.2 N·m) Static neutralizing performance is deteriorated when the nozzle is loose.
Page 7
Doc. no.IZ*-OMX0012 4) Keep within the specified ambient temperature range. Ambient temperature range is 0 to 40 C. Do not use the product in locations where the ambient temperature changes suddenly even within the specifications or if the temperature difference of the fluid relative to the ambient temperature is large condensation may occur.
Page 8
Doc. no.IZ*-OMX0012 4) Do not directly touch the emitters. Do not touch the end of the emitters. They have a sharp end and touching them directly with your fingers may cause injury. 5) Do not disassemble or modify the product. Disassembling or modifying the product may cause product, electric shock or fire.
Doc. no.IZ*-OMX0012 1. How to Order 1-1. Ionizer IZG10 - 08 01 - 01 Ionizer-Gun type Nozzle type One-touch fitting Symbol Type Symbol Applicable tube O.D. ø8 (mm) Standard nozzle - The nozzle specified for the product.Do not use other ø5/16”...
Doc. no.IZ*-OMX0012 1-3. Repair parts Emitter assembly IZG10-NT Protection cap (Remove when used) Nozzle assembly IZG10-A001-01 Cleaning kit IZS30-M2 IZS30-A0201 IZS30-A0202 (フェルト、ゴム砥石各1個、 (替フェルト10個入) (替ゴム砥石1個入) (Provided together with 1 felt pad (Provided together with 10 (Provided together with 1 replacement 替フェルト2個付属)...
AC adapter (with AC cord) Note) The rated voltage of the AC cord supplied with IZG10-□01 is 125V, and the plug is JIS C8303 type B, which is for Japanese domestic use. If the product is used in an area other than rated voltage (220 or 240VAC), select IZG10-□02 without AC power cord and prepare an AC cord with ground terminal inlet IEC60320-C13 adapted to the power supply voltage.
Doc. no.IZ*-OMX0012 4. Function 4-1. Name of parts LED indication Inside of the slide cover (6) (7) Name of parts Name Description Nozzle Blows ionized air. Slide cover Protective cover for the mode setting switch. Mode setting switch Switch for setting blow and trigger. (Default setting: Setting No.0) Adjust the flow by rotating the handle.
Doc. no.IZ*-OMX0012 4-3. Mode setting switch - Blow or trigger can be selected by switching the mode setting switch. Note) - Open the slide cover over the mode setting switch and rotate the dial to the set number (No.0 to 9) while referring to the table below.
Doc. no.IZ*-OMX0012 4-4. Emitter maintenance (cleaning and replacement) - If the product is used for an extended period of time with foreign matter on the emitters, the static neutralizing performance of the product will be reduced. Clean the emitters regularly. (Emitter contamination level is different depending on the installation environment and supply pressure.) - This product is equipped with a function that monitors the amount of discharge from the emitter and turns on the maintenance indicator LED when the amount of discharge decreases.
Page 15
Doc. no.IZ*-OMX0012 ― Removing the nozzle and emitter assembly ― - Be sure to stop the power supply and compressed air supply to the product. - Remove the nozzle by turning it by hand in direction shown below. - Pinch the white shaded part of the emitter assembly using pliers, and remove it by turning as shown below.
- Ion generation continues even when the maintenance indicator LED is ON. - If the emitter is worn or damaged, an alarm may be output continuously. In this case, replace the emitter assembly (IZG10-NT).
Doc. no.IZ*-OMX0012 5. Performance Performance given in this chapter is based on an electrified plate (dimensions: 150 x 150mm, electrostatic capacity: 20pF) defined by ANSI standard (ANSI/ESD STM3.1-2015). Use this data as a guideline for selection, as the performance data may vary depending on the material and size of the work piece. 5-1.
Page 20
(Not included with IZG10-CG2) Models AC cord IZG10-CG1 Included IZG10-CG2 Not included Power supply cable (24VDC) / IZG10-CP Semi-stripped terminal Power supply cable (24VDC) Cable specification Number of cable wire / Size 4pcs. / AWG26 Nominal cross section of the 0.15mm...
24VDC +/-5% Output current 0.8A max Ambient temperature 0 to 40 Ambient humidity 20 to 80%Rh Applicable standard/directive CE cUL Note 1) AC cord for IZG10-CG1 is only for use in Japan (Rated voltage: 125V, Plug: JIS C8303, Inlet: IEC60320-C13).