Operation Mode Service Utility Water; Operation Mode Summer - ATTACK ELECTRIC EASY Series Instructions For Use Manual

Wall hung electric boiler
Table of Contents

Advertisement

Regulation is controlled on the basis of the temperature
setting of heating water and hysteresis.
Setting of heating water temperature:
Set the temperature requested on the control panel
using the buttons ,
(during setting the point between
numbers are lighting) and confirm by
confirmation the temperature value set blinks for a
minute and the setting marking is lost. The boiler now
heats for temperature set by you. The scale for
temperature setting is from 30 to 80° C (if you set the
temperature below 30° C on the display there is the
marking LE- summer regime, possibility to go back is by
pushing .
If you don´t confirm the temperature setting till 5 s, the
boiler turns to the setting before. Use the room
thermostat for economical operation of your heating
system.
With the room thermostat connected
9
4
In case that you use the room thermostat in your heating
system the regulation of heating water temperature is
controlled similar till the moment when the request for
heating is terminated (the temperature set on the room
thermostat is fullfiled and the room thermostat is switch
off).
6
5
5
1 - boiler
4 - heating system
5 - shut off valve
6 - filter
9 -room thermostat

2.3.2 Operation mode service utility water

(on the display there is
. After
4
1 - boiler
2 - storage water tank
3 - 3ways motoric valve
4 - heating system
5 - shutt of valve
6 - filter
7 - back flap
In case that you will heat service utility water through
the storage water tank (the thermostat of tanks is switch
on) the temperature regulation of service utility is
controlled to value 85° C. This temperature is not
possible to change. If the request for service utility water
temperature is fulfilled (the thermostat of tank is switch
off) the boiler returns to mode of heating water (heating
water or mode summer).
This regime for boiler is automatic, is not possible to
change it by the user.
2.3.3 Operation mode summer (on the display
there is LE)
The boiler has not any reaction for the request of heating
(room thermostat) and doesn't heat the system. The
boiler accepts only request for service utility water
heating and work like in the point 2.3.2 operation mode
Service utility water.
ГB)
9
3
AB
6
B
A
M
5
5
5
5
12
2
8 - treatment of water
9 - room thermostat
11 - consumption place
12 - safety valve
13 - expansion vessel
15 - storage tank sensor
15
11
13
5
7
8
12