Attaching The Coupling Block To The Gear Reduction Unit - Emerson Bettis XTE3000 Installation, Operation And Maintenance Manual

Electric actuator
Table of Contents

Advertisement

Installation, Operation and Maintenance Manual
MAN-02-04-97-0713-EN Rev. 1
Figure 14
Extract the bushing and machine it according to the mating needs.
Figure 15
3.2.3.2
Re-assembling the Internal Parts
It is advisable to wash the dismantled parts with a suitable solvent and dry them with
compressed air. Make sure that no metal filings or foreign bodies remain; spread a film of
grease on all parts (for grease type see Section 4, Lubrication).
Proceed with the assembly of the internal parts by following the disassembly procedure in
reverse order. Attach the unit to the gear reducer as described further on.
3.2.4

Attaching the Coupling Block to the Gear Reduction Unit

Check the integrity of the O-ring seal and place it in its slot on the coupling block.
Ensure that the lugs of the drive sleeve fit in the correct slots on the bushing.
Attach the screws previously removed.