Installation Through Side Of Masonry Chimney; Insert Installations - Breckwell SP24i Owner’s Instruction And Operation Manual

Table of Contents

Advertisement

6. Measure and build chimney top plate. Cut out holes for
chimney pipe, and if used the outside air pipe. Install
and seal with non-hardening mastic to prevent water
leakage. Install vent cap.
E. INSTALLATION THROUGH SIDE OF MASONRY
CHIMNEY
NOTE:
FOLLOW METAL
CHIMNEY
INSTALLATION
INSTRUCTIONS
OPTIONAL
OUTSIDE AIR
TRIM COLLAR
TO STOVE
NOTE: Follow L-Vent chimney manufacturer's instructions.
1. Position the stove, adhering to the clearances provided
in this manual. Mark the center of the hole where the
pipe is to pierce the masonry chimney.
2. It will be necessary to break out the masonry around the
location of the pipe center mark. Use a 4-inch diameter
hole for 3-inch pipe and 5-inch diameter hole for 4-inch
pipe.
3. Measure and build chimney top plate. Cut out holes for
chimney pipe, and if used the outside air pipe.
4. Install the tee on the bottom of the vertical pipe system
and lower it down the chimney until the center branch
of the tee is level with the center of the hole in the
masonry.
5. Install and seal the top plate from step 3 with non-
hardening mastic. Slip the storm collar over the pipe,
and while holding the pipe at the proper elevation, affix
the collar with a minimum of three 1/4" stainless steel
sheet metal screws. Seal all joints and seams around
the collar.
© 2020 Breckwell Hearth
6. Connect the horizontal pipe by pushing it through the
7. If desired, once the horizontal pipe is in place, the
TOP PLATE
8. Install the trim collar. An adjustable pipe length and
(SEAL TO CHIMNEY
TOP WITH
NON-HARDENING
MASTIC)

INSERT INSTALLATIONS

EXTENSION TO
Insert installations must be vented with 3" or 4" pipe. Pipe
CHIMNEY TOP
may be single wall stainless steel flexible pipe. Vent may
REQUIRED.
terminate within chimney beyond a blanking plate or extend
to the chimney top. See "COMBUSTION AIR SUPPLY" for
outside air access information. The fireplace and chimney
should be cleaned thoroughly before starting the installation.
We suggest painting the interior of particularly old and dirty
fireplaces to seal any odors.
3" OR 4"
STAINLESS STEEL
SINGLE WALL PIPE
OR FLEX PIPE.
PIPE ADAPTER
CLEAN-OUT-TEE
(TYPE L)
A. ASSEMBLING THE FLASHING SET
Follow the instructions packaged with the flashing set.
B. WHEN VENT PIPE EXTENDS TO CHIMNEY TOP
1. You will need a pipe length equal to the chimney height
10
hole in the masonry and lining it up with the branch in
the tee. Push the pipe into the tee while twisting it to
lock it into the tee.
space between the pipe and masonry may be filled
with high-temperature grout.
adapter may be needed to finish the connection to the
stove.
Zero Clearance Short (2 piece)
Adjustable From 3-1/2" to 6"
(from hearth) plus 6 inches. If outside combustion
INSTALLATION

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents