REMOTE CONTROL
Remote control (CI-V) information
D Command formats
• Manually entered position data
Command: 1A 05 0286, 0312, 0326,
23 02
6 ~ 11
1 ~ 5
X X
X X
X X
∙∙∙∙∙∙∙
∙∙∙∙∙∙∙
1
2 3 4 5 6 7 8 9 10 11 12 13 14 15
X X X X X X X 0 0 X 0 X X X X X X X X 0 0 X X X X X X X 0 X
Latitude
1 ~ 5: Latitude (dd°mm�mmm format)
6 ~ 11: Longitude (ddd°mm�mmm format)
12 ~ 15: Altitude (0�1 meter steps)
* When reading the contents with no altitude, sends
12, 13, 14, and 15 as "FF�"
* When sending the contents with no altitude, set 12,
13, 14, and 15 to "FF�"
• D-PRS Symbol setting
Command: 1A 05 0291 ~ 1A 05 0294,
1A 05 0310, 0324, 0335
X
X
X
X
First digit
Second digit
• ⁄,\,0to9,AtoZcanbeusedforthefirstdigit
character�
• See "Codes for character entries" for the second
digit character� (p� 18)
12 ~ 15
X X
X X
X X
∙∙∙∙∙∙∙
*
*
:
Longitude
Altitude
• Alarm area (Group) setting
Command: 1A 05 0346
1
X
X
*
*
• Data mode with filter width settings
Command: 1A 06
00=Data mode OFF*
01=Data mode ON
*
When 00 is set, also set 00 to 2�
• Repeater tone/tone squelch frequency settings
Command: 1B 00, 1B 01
1*
0
0
*Not necessary when setting a frequency�
• DTCS code and polarity setting
Command: 1B 02
1
X
X
21
2
3
X
X
X
0
1
2
X X X X
01=FIL1
02=FIL2
03=FIL3
2
3
X
X
X
X
2
3
0
X
X
X
Receive polarity: 0=Normal
1=Reverse
Transmit polarity: 0=Normal
1=Reverse