Page 2
Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
........................General wiring guidelines ......................Connection..........................Connection example ......................... Download modified project to the PNOZmulti system .............. Operation ..........................Messages ..........................Technical details ........................Safety characteristic data ......................Order reference ........................Product ............................. Accessories ..........................Operating Manual PNOZ mo3p 21134-EN-07...
Page 4
Contents Supplementary data ......................10.1 Maximum capacitive load C (μF) with load current I (mA) at the semiconductor outputs..Operating Manual PNOZ mo3p 21134-EN-07...
Introduction Introduction Validity of documentation This documentation is valid for the product PNOZ mo3p. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
Page 6
Introduction INFORMATION This gives advice on applications and provides information on special fea- tures. Operating Manual PNOZ mo3p 21134-EN-07...
Scope Expansion module PNOZ mo3p Jumper Unit features Application of the product PNOZ mo3p: Expansion module for connection to a base unit from the configurable control system PNOZmulti The product has the following features: Can be configured in the PNOZmulti Configurator...
A competent person is someone who, because of their training, experience and current pro- fessional activity, has the specialist knowledge required to test, assess and operate the work equipment, devices, systems, plant and machinery in accordance with the general standards and guidelines for safety technology. Operating Manual PNOZ mo3p 21134-EN-07...
System requirements Please refer to the "Product Modifications PNOZmulti" document in the "Version overview" section for details of which versions of the base unit and PNOZmulti Configurator can be used for this product. Operating Manual PNOZ mo3p | 10 21134-EN-07...
System reaction time Calculation of the maximum reaction time between an input switching off and a linked out- put in the system switching off is described in the document "PNOZmulti System Expan- sion". Operating Manual PNOZ mo3p | 11 21134-EN-07...
Electrostatic discharge can damage components. Ensure against discharge before touching the product, e.g. by touching an earthed, conductive sur- face or by wearing an earthed armband. Dimensions in mm 22,5 94 (3.70") (0.88") Operating Manual PNOZ mo3p | 12 21134-EN-07...
Please refer to the document "PNOZmulti System Expansion" for details of the number of modules that can be connected to the base unit and the module types. Operating Manual PNOZ mo3p | 13 21134-EN-07...
Version 2.0. – On earlier versions of the base units, unused outputs must be loaded with a resistance of less than 3 kOhm. Example: R = 2.7 kOhm, 0.3 W at 24 V. Operating Manual PNOZ mo3p | 14 21134-EN-07...
PNOZmulti Configurator and downloaded back into the base unit. Proceed as described in the operating manual for the base unit. NOTICE For the commissioning and after every user program change, you must check whether the safety devices are functioning correctly. Operating Manual PNOZ mo3p | 16 21134-EN-07...
External error, which leads to a safe state; the fault is at the outputs whose LEDs are flashing, e.g. short across the contact External error on the output Internal error on the expansion module Operating Manual PNOZ mo3p | 17 21134-EN-07...
In accordance with the standard EN 60068-2-14 Temperature range 0 - 60 °C Forced convection in control cabinet off 55 °C Storage temperature In accordance with the standard EN 60068-2-1/-2 Temperature range -25 - 70 °C Operating Manual PNOZ mo3p | 18 21134-EN-07...
Page 19
2 core with the same cross section, flexible without crimp connectors or with TWIN crimp connectors 0,25 - 0,75 mm², 24 - 20 AWG Torque setting with screw terminals 0,25 Nm Stripping length with screw terminals 7 mm Operating Manual PNOZ mo3p | 19 21134-EN-07...
A safety function's SIL/PL values are not identical to the SIL/PL values of the units that are used and may be different. We recommend that you use the PAScal software tool to calculate the safety function's SIL/PL values. Operating Manual PNOZ mo3p | 20 21134-EN-07...
1 set of spring-loaded terminals 783 400 Set screw terminals 1 set of screw terminals 793 400 Terminator, jumper Product type Features Order no. PNOZmulti bus terminator Terminator 779 110 KOP-XE Jumper 774 639 Operating Manual PNOZ mo3p | 21 21134-EN-07...
Page 22
Supplementary data Supplementary data 10.1 Maximum capacitive load C (μF) with load current I (mA) at the semiconductor outputs C (µF) 1000 1200 1400 1600 1800 2000 I (mA) Operating Manual PNOZ mo3p | 22 21134-EN-07...
Page 23
We are represented internationally. Please refer to our homepage www.pilz.com for further details or contact our headquarters. Headquarters: Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com, Internet: www.pilz.com...
Need help?
Do you have a question about the PNOZ mo3p and is the answer not in the manual?
Questions and answers