6.11
Disabling function
This function is implemented since the FW version 5.08.
The
module disabling function
port. The logic of the function is individually configurable. The function is active whenever
one or both of the configured inputs are active.
The module behavior is as described below when the disabling function is active:
•
User with access driven by a time schedule cannot run the door open function
•
User with access always granted is not affected by the disabling function
•
Remote door open function cannot be performed
•
Remote identification with ID is disabled for users with access driven by a time schedule
The disabling status changes and disabled actions are logged in the events archive.
6.12
Reading synchronization
Since the
FW version 5.09
implemented, enabling to
offers to use the
IO synchronization
port 3
is used as the
6.13
Online authorization
Since the
FW version 5.11
system. When the feature is used, the ID validity is resolved in connected PC. To be able to
use this authorization mode, the reader module has to be equipped with a
can be set at the second input and at the third input / output
the reading synchronization of a
cancel the mutual disturbance
in both
synchronization
signal.
the
Online authorization of ID
Page 18
couple of TECHFASS readers
of the modules. The reader module
MASTER
and
SLAVE
can be used in APS mini Plus
mode. The
input/output
MLO
license.