4.2 Standard connection

Input 1
Input 2
Output 1 (transistor)
Alarm output
I/O Port 3
The door monitoring contact (IN1) is operational after its first change of status since
switching on the module. Full door lock timing acc. to tab. 8 is used when the door status
contact is not installed and no Forced Door and Door Ajar alarms are triggered.

4.3 LED Indicators

D1 – upper LED; D2 – middle LED; D3 – lower LED
D1
Red-green
D2
Yellow
D3
Green

4.4 Installation instructions

The reader module uses passive RF/ID technology, which is sensitive to RF noise sources.
Noise sources are generally of two types: radiating or conducting.
Conducted noise enters the reader via wires from the power supply or the host. Sometimes,
switching power supplies generate enough noise to cause reader malfunction, it is
recommended to use linear system power supplies.
Radiated noise is transmitted through the air. It can be caused by computer monitors or other
electrical equipment generating electromagnetic fields.
Consequently, a short distance between the reader modules themselves can cause reading
malfunctions – for correct operation it is necessary to keep a minimum distance of 50 cm.
Various metallic constructions may have a negative influence on this distance; if there are
any doubts, it is recommended to perform a practical test before final mounting.
Door contact, active when door closed; REX button
Request to exit button or handle contact, active when button or
handle pressed; Tamper; Disabling function
Door lock control (configurable polarity, default 0V for lock release)
Low power transistor output (+5 V in any alarm state)
External tamper (Standard operating mode)
External reader buzzer control (op. mode with entry reader)
Disabling function
Reading synchronization: MASTER / SLAVE mode
Continuously lit (red)
Flashing with 4 s period (red)
Fast switching (red / green)
Single flash (green)
Continuously lit / flashing
Short flashing with 1s per.
Page 6
Table 6: Standard connection
Online operating mode
Offline operating mode
Address setting mode;
RS 485 BUS testing mode
ID media reading
Programming mode
Indicating door lock release
(configurable)
Indicating door lock release
Table 7: LED indicators

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mrem 65 bkMrem 65 grMrem 65 – tfMrem 65 – emMrem 65 gr – tfMrem 65 gr – em ... Show all

Table of Contents