6 In case of problems adjust the following VDL200 parameters

Problem
At Start there is a delay to
release the brake and there
is a car shock.
At Start the acceleration is
to sharp.
After the start the
acceleration is to sharp.
The first phase of the
deceleration is to sharp.
The deceleration to
approach the floor is to
sharp.
During the landing phase
the speed is not smooth but
with jumps.
At Stop there is a delay to
close the brake.
At Stop there is a shock.
For elevator in close loop,
during the travelling at the
rated speed there are
vibrations.
The short floor is not
optimized.
Rollback at Start for Open
Loop Control or the car is
not able to start.
Replace AGy-L by VDL200
Cause
The Motor starts running when the
brake is not completely released or
runs against the brake
The Acc ini Jerk value is too high
The linear acceleration value is too
high
The Dec ini Jerk value is too high
The deceleration value is too high
The configuration of the brake
closure timing is not optimized
The brake closes before of the
motor stop.
The Speed control loop is not well
set.
The parameters related to the short
floor are not well optimized.
There is no enough current.
Action
Parameters
Increase the Brake
11064 Menu (5.3.3)
Open Delay
Decrease the Acc ini
11040 Menu (5.2.1)
Jerk value
Decrease the Acc
11042 Menu (5.2.2)
value
Decrease the Dec ini
11046 Menu (5.2.4)
Jerk value
Decrease the Dec
11048 Menu (5.2.5)
value
In case of Asyn
motors increase the
Slip Compensation
2440 Menu (19.10)
and/or increase the
(Asyn motors only)
slow speed.
In case of Synch
11120 Menu (5.5.9)
motors increase the
slow speed
Decrease the Brake
11068 Menu (5.3.5)
close Delay
Increase the Brake
11068 Menu (5.3.5)
close Delay
2200 Menu (16.1)
Decrease the
Proportional Speed
2204 Menu (16.2)
Regulation Gains.
2206 Menu (16.3)
11046 Menu (5.2.4)
Adjust the related
parameters to have
11048 Menu (5.2.5)
the best
11050 Menu (5.2.6)
Tune the parameters
to modifying the V/f
2408 – 2410 – 2412 –
curve to provide
2414. Menu (19.5.x)
higher torque at lower
Voltage.