PLC Memory Map

Please refer to table II below for PLC inputs, outputs, special "settable" internal control registers and settable
internal timers with accompany description.
Input
Output
Registers
000
001
002
003
004
005
006
007
500
501
502
503
504
505
DM0075
DM0080
DM0100
DM0105
TAM Application Monitor - Yype 21800
Page 36
44-0009-2048-6 / ECO# 0078483
Timers
Description
Current Sensor
UPPER – Low Tape Proximity Sensor
Photo Eye - Box Present Sensor
LOWER – Low Tape Proximity Sensor
LOWER – Tape Dispense Proximity Sensor
SPARE - Not in Use
UPPER – Tape Dispense Proximity Sensor
SPARE - Not in Use
SPARE - Not in Use (AC Voltage Common)
"Optional" Remote AC (120/240) Beacon Light
Case Sealer - Solid State Relay
"Optional" Dry Contact Relay. This output is used to stop an 800rks or 800rf
in the event of a fault condition. This output could also be used to halt an
external conveyor or signal a host controller. Output is normally ON and is
OFF under a fault condition.
SPARE - Not in Use (DC Voltage Common)
Panel Indicator Light 24V DC
System Confi guration Register (31=Lower Only, 32=Upper Only,
3=Both Taping Heads). Factory setting DM0075 = 33.
By-Pass Register (1=By-Pass Enable, <>1 = Normal TAM Operation.
Factory setting DM0080 = 0.
Taping Head off set distance (0 = Standard 1 = Off set).
Case Sealer Belt Speed (0=15 ips 1=20 ips 2=30 ips).
TH051
Represents the distance in "time" from the box present sensor to within ½"
from the end of the lower taping head cut-off bracket (i.e. just before the
tape would cut). When possible the box present sensor should be positioned
very near the lower taping head cut-off bracket so the value of TH051 is small.
In cases where this is not possible position the sensor just in front of the
lower taping head apply roller. However, if there is no lower taping head
used then position the box present sensor as close to the upper cut-off
bracket.
Note: In all cases position the sensor to trigger before the tape would cut.
As an example for a 15 ips case sealer belt speed and a box present
sensor positioned to trigger ½" before the tape would cut TH051,
would be set to 3 hundreds of a second [TH051 = distance/velocity =
(1/2/15)*100]. In applications where only an upper taping head is
used (i.e. DM0075 = 32) TH051 represents the time in hundreds of
a second from the box present sensor to just before the upper taping
head cuts. Factory Setting TH051 = 2.