Specifications

6.1 Specifications, Controller ST4-C11

Item
Supply voltage
Current consumption
Control output
OSSD1/2 (Note 1)
Auxiliary output (Note
1)
Protection
Ambient temperature
88
SEN TRONIC
AG
Produkte, Support und Service
Description
24V DC
+10
% Ripple P-P 10% or less
-15
0.1A or less
PNP or NPN open-collector transistor. Select PNP or NPN output with switch.
PNP output
• Max. source current: 200mA
• Applied voltage: same as the supply voltage (between control
output and +V)
• Residual voltage: 2.5V or less (at 200mA source current)
• Leakage current: 200µA or less (also in power OFF state)
• Maximum load capacity: 1µF (with or without load)
Load wiring resistance: 3Ω or less
NPN output
• Max. 200mA sink current
• Applied voltage: same as the supply voltage (between control
output and 0V)
• Residual voltage: 2.0V or less (at 200mA sink current)
• Leakage current: 200µA or less (also in power OFF state)
• Maximum load capacity: 1µF (with or without load)
Load wiring resistance: 3Ω or less
Output operation
• ON when all beams of the connected ST4-A□s are received.
OFF when one or more beams of the connected ST4-A□s are
interrupted
Short circuit
protection
Response time
• Turn-off time: 25ms or less
Turn-on time: 90ms or less (auto-reset)/140ms or less (manual
reset)
PNP or NPN open-collector transistor. Select PNP or NPN output with switch.
PNP output
• Max. source current: 100mA
• Applied voltage: same as the supply voltage (between auxiliary
output and +V)
Residual voltage: 2.5V or less (at 100mA source current)
NPN output
• Max. 100mA sink current
• Applied voltage: same as the supply voltage (between auxiliary
output and 0V)
Residual voltage: 2.0V or less (at 100mA sink current)
Output operation
• OFF when all beams of the connected ST4-A□s are received.
ON when one or more beams of the connected ST4-A□s are
interrupted
Short circuit
protection
Enclosure: IP40 (IEC), Terminal area: IP20 (IEC)
-10 to +55°C
(No dew condensation or icing allowed),
Rugghölzli 2
CH - 5453 Busslingen
Panasonic ST4 Instruction Manual