4.2 Periodic Inspection Checklist (Every Six Months)

!
Check
Inspection item
column
The structure of the machine does not obstruct any of the safety mechanisms designed for stopping
the operation.
No modification has been made in the machine controls which obstructs the safety mechanisms.
The output of this device is detected correctly.
The wiring from this device is correct.
The overall response time of the complete machine is equal to or less than the calculated value.
The actual number of operation cycles (time) of the limited lifetime parts (relay, etc.) is less than their
rated operation cycles (time).
No screws or connectors of this device are loose.
No extraneous light source or reflective object has been added near this device.