3.3 Emission Halt Function

!
The emission halt input is incorporated in the controllers ST4-C11 and ST4-C12EX. This
function stops the emission process of the ST4-A□. You can select whether emission is on or
halted by wiring the terminals T1 and T2 as shown in the following table.
Between T1 and T2
Open
Short-circuit
During emission halt, the control output (OSSD 1/2) is off and the emission halt indicator
(orange) lights up.
If the machinery is not stopped, the cause may be a malfunction due to extraneous noise or an
abnormality in the control output (OSSD 1/2) or the auxiliary output, also from the machine.
Open
Reset input
0V/+V
Open
Emission halt
Short-
input
circuit
Emission
Emission
Emission
condition
halt
ON
Control output
(OSSD 1 / 2)
OFF
Time chart for manual reset
Open
Emission
halt input
0V/+V
Emission
Emission
Emission
condition
halt
ON
Control output
(OSSD 1 / 2)
OFF
Time chart for auto reset
SEN TRONIC
AG
Produkte, Support und Service
WARNING!
Do not use the emission halt input to stop machinery! This could
result in serious injury or death.
Operation
Emission halt
Emission
40ms or more
40ms or more
25ms or less
40ms or more
25ms or more
Rugghölzli 2
CH - 5453 Busslingen
3.3 Emission Halt Function
120ms or more
140ms or less
40ms or more
90ms or less
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
53