Emission Amount Adjustment Function - Panasonic ST4 Instruction Manual

Safety beam sensor
Hide thumbs Also See for ST4:
Table of Contents

Advertisement

Panasonic ST4 Instruction Manual
Time chart for manual reset
Beam
received
Reception
status
Beam
interrupted
ON
Control output
(OSSD 1 / 2)
OFF
Auxiliary output
ON
(Negative logic
OFF
of OSSD)
Time chart for auto-reset

3.5.3 Emission Amount Adjustment Function

!
This function is incorporated in the ST4-A□V. It is used to reduce the emission amount so that
the emitted beam of ST4-A□V will not be received as extraneous light from the other sensors.
The emission amount can be reduced by turning the emission amount adjuster on the emitter of
ST4-A□V to the MIN. side.
SEN TRONIC
AG
Produkte, Support und Service
20ms or less
20ms or less
DANGER!
The emission amount adjuster of the ST4-A□V is used to
reduce the beam emission of the ST4-A□V to prevent
influencing other sensors.
Do not use the emission amount adjuster of the ST4-A□V to
prevent the reflection off surfaces. If it is used for such
purposes and the emission amount adjuster is set at MAX.,
the reflection off surfaces increases. This may disable the
sensor from detecting objects, which could result in serious
injury or death.
To cope with reflective surfaces, see "Influence of Reflective
Surfaces" on page 20 .
Rugghölzli 2
CH - 5453 Busslingen
3.5 Auxiliary Output
90ms or less
20ms or less
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
57
mailbox@sentronic.com
www.sentronic.com

Advertisement

Table of Contents
loading

Table of Contents