Fault Code - Bosch TCA640 Series Repair Instruction

Fully-automatic coffeemaker
Table of Contents

Advertisement

7.4.11 Individual test
The following options can be selected:
Upgrading factory settings
(the latest parameters are transferred from the PC to the appliance)
Statistics
(Only data is read out of the appliance without any change to the
current appliance status)
Configuration of the input diagnostic (short / long)
(a "short / static" or "long / dynamic" input diagnostic can be selected.
Recommendation = dynamic diagnostic)
Resetting the grinding time
Reset to "initial start up"
(normal = 10 sec./initial start up = 13 sec.)
or keep the current grinding unit running time.
7.4.12 Statistics
The statistical data can be displayed via the individual test.
7.4.13 Output diagnostic
Customer data from the input diagnostic is saved back in the machine.
(Production, statistical, service, customer data)
Dynamic diagnostic similar to final inspection during production and
input diagnostic, however without external power and temperature
measurement, however with evaporation of the heating cartridge.
Input service entry via input mask (see service stamp)
Identical to the input diagnostic, a report is also prepared here with the
same processing options.
58300000120060_ARA_en_c.doc – 18.09.09
7.4.14 Service stamp
The service stamp is input via the following form:
7.4.14.1 Group definition
Specific fault groups are allocated to the working points. When a
working point has been selected, its fault group is activated for
selection in "Input fault code".
A690 = Instantaneous water heater replaced,
Fault group
F 4 00 = Coffee water heater blocked
7.4.14.2 Service stamp structure
This concept of the service stamp enables each service centre to
evaluate what work was carried out during the last service and which
faults were rectified. In all 3 service entries are saved in the appliance.
The first stamp is never overwritten. In the case of stamps 2 and 3 the
older stamp is overwritten. Therefore it is always obvious when the 2
previous services were carried out.
The definitions as work/fault codes, major faults, employee number
and number of services are included only in the last service entry
in the appliance.
The service date, number of the service centre and invoice item are
saved for all three entries.
4
Seite 82 von 95

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tca680 series

Table of Contents