Replacing The Thermal Fuse - Bosch TCA640 Series Repair Instruction

Fully-automatic coffeemaker
Table of Contents

Advertisement

6.4

Replacing the thermal fuse

The thermal fuse (STB) is a safety element which is
used to prevent damage caused by the heater
overheating. To ensure correct function, it is essential to
install the thermal fuse properly.
Whenever the appliance is repaired, check as
a precaution that the thermal fuse is in perfect
condition and is correctly installed!
6.4.1
Checking an installed thermal fuse:
The following points must be checked:
Position and attachment of the Teflon hose (must be firmly
anchored)
Position of the thermal fuse (centred under installation
bracket)
Quality of the cable connections
Bend correct
Installation bracket is firmly attached
6.4.2
Component
The thermal fuse is supplied as a pre-assembled component.
(Wire colour and type may deviate in reality).
58300000120060_ARA_en_c.doc – 18.09.09
6.4.3
Installation location
1
Screw with circlip
2
Installation bracket
3
Heater
Seite 56 von 95