7.1.5
Cleaning and descaling programme
Complaint
Cleaning programme does
not start
Cleaning programme stops
after addition of cleaning
tablet
Error message "Error 8" is in-
dicated
Descaling programme does
not start
Descaling programme runs
for too long
Descaling display does not
go out after descaling
58300000120060_ARA_en_c.doc – 18.09.09
Cause?
►
System too hot (message on display)
►
Ground coffee flap is not closed
►
No ground coffee duct flap or no magnet on
ground coffee duct flap
►
Reed switch for detecting the ground coffee duct
flap defective
►
Cleaning tablet added at wrong time. Cleaning
tablet is blocking brewing unit
►
System too hot (message on display)
►
Water filter inserted and active
►
Too much liquid in water tank
►
Request to empty trays is indicated. Descaling
programme interrupted
►
Descaling was ended prematurely
Remedial action
►
Cool down system by drawing hot water
►
Close ground coffee duct flap and press the
coffee dispensing button
►
Replace ground coffee duct flap with magnet
►
Replace reed switch
►
Remove and clean brewing unit, remove
cleaning tablet
►
If damaged, replace brewing module
►
Cool down system by drawing hot water
►
Remove water filter and change programming
►
Adjust water hardness
►
Observe 0.5 l mark on water tank
►
Empty trays, clean contacts and dry
►
Restart descaling and run from start to end
Seite 69 von 95