HS5E Miniature Interlock Switches with Solenoid
Four-circuit Independent Output - Spring Lock
Interlock Switch Status
Door Status
Circuit Diagram (HS5E-VA4)
Door
Door Monitor
Lock Monitor
(Actuator Inserted)
(Solenoid OFF)
(+)
A2
HS5E- VA4
Monitor Circuit:
11
12
41
Monitor Circuit:
23
24
Monitor Circuit:
53
HS5E-VB4
Monitor Circuit:
11
12
41
Monitor Circuit:
23
24
Monitor Circuit:
51
HS5E-VC4
11
12
41
Monitor Circuit:
Monitor Circuit:
21
22
Monitor Circuit:
53
HS5E-VD4
11
12
41
Monitor Circuit:
21
22
Monitor Circuit:
51
Monitor Circuit:
Solenoid Power A1-A2 (all model)
The above contact confi guration shows the status when the actuator is inserted and locked.
Monitor Circuit: Sends monitoring signals of protective door open/closed status or protective
door lock/unlock status.
Operation Chracteristics (reference)
0 (Actuator insertion position)
Monitor Circuit (door open, NO)
Monitor Circuit (door closed, NC)
Monitor Circuit (unlocked, NO)
Monitor Circuit (locked, NC)
714
Status 1
Door Closed
Machine ready to
operate
Solenoid de-energized
(+)
(–)
A2
A1
11
12
41
42
23
24
53
54
Closed (locked)
Monitor Circuit
ON (closed)
(door closed)
11−12
(–)
Monitor Circuit
A1
OFF (open)
(door open)
23−24
Monitor Circuit
ON (closed)
(locked)
42
41−42
54
Monitor Circuit
OFF (open)
(unlocked)
53−54
Monitor Circuit
ON (closed)
(door closed)
11−12
Monitor Circuit
OFF (open)
(door open)
23−24
Monitor Circuit
42
ON (closed)
(locked)
41−42
52
Monitor Circuit
ON (closed)
(locked)
51−52
Monitor Circuit
ON (closed)
(door closed)
11−12
Monitor Circuit
ON (closed)
(door closed)
21−22
42
Monitor Circuit
ON (closed)
(locked)
41−42
54
Monitor Circuit
OFF (open)
(unlocked)
53−54
Monitor Circuit
ON (closed)
(door closed)
11−12
Monitor Circuit
ON (closed)
(door closed)
21−22
Monitor Circuit
42
ON (closed)
(locked)
41−42
52
Monitor Circuit
ON (closed)
(locked)
51−52
OFF (de-energized)
3.3 (Locked position)
5.3
6.9
26.4 (travel in mm)
Contacts ON (closed)
Contacts OFF (open)
Status 2
Status 3
Door Closed
Door Open
Machine cannot be
Machine cannot be
operated
operated
Solenoid energized
Solenoid energized
(+)
(–)
A2
A1
11
12
41
42
11
23
24
53
54
23
Closed (unlocked)
Open
ON (closed)
OFF (open)
OFF (open)
ON (closed)
OFF (open)
OFF (open)
ON (closed)
ON (closed)
ON (closed)
OFF (open)
OFF (open)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
OFF (open)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
ON (closed)
ON (closed)
OFF (open)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
ON (energized)
ON (energized)
Note: Actuator can be unlocked manually for confi rming the
door movement before wiring and energizing, and also for
emergency situation such as power failure.
The operation characteristics shown in the chart above are of the HS9Z-A51.
For other actuators, add 1.3 mm.
The operation characteristics show the contact status when the actuator enters
the entry slot of an interlock switch.
Unlocked with Manual
Status 4
Unlocking Key
Door Open
Door Closed
Machine cannot be
Machine cannot be
operated
operated
Solenoid de-energized
Solenoid de-energized
LOCK
UNLOCK
(+)
(–)
A2
A1
11
12
12
41
42
23
24
24
53
54
Open
Closed (unlocked)
OFF (open)
ON (closed)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
ON (closed)
OFF (open)
ON (closed)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
OFF (open)
ON (closed)
OFF (open)
OFF (open)
ON (closed)
ON (closed)
OFF (open)
ON (closed)
OFF (open)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (de-energized)
OFF (de-energized)
LOCK
UNLOCK
Turn the manual
unlock key (Note)
(+)
(–)
A2
A1
41
42
53
54