IDEC HS6B Series Instruction Sheet

IDEC HS6B Series Instruction Sheet

Interlock switch

Advertisement

Quick Links

INSTRUCTION SHEET - HS6B Series
INSTRUCTION SHEET
Original Instructions
Interlock Switch
HS6B Series
Confirm that the delivered product is what you have ordered.
Read this instruction sheet to make sure of correct operation.
S A F E T Y P R E C A U T I O N S
In this operating instruction sheet, safety precautions are categorized to Warning and
Caution:
WARNING
Warning notices are used to emphasize that improper operation may cause severe
personal injury or death.
CAUTION
Caution notices are used where inattention might cause personal injury or damage to
equipment.
1
Type
Interlock switch
Actuator
HS6B-11B01
HS9Z-A61
Contact Configuration
Cable Length
11:1NC-1NO
01:1m
02:2NC
03:3m
12:2NC-1NO
05:5m
03:3NC
Note : Select an actuator that moves in the direction required by the hinged door and
interlock switch.
2
Specifications and Ratings
Applicable Standards
EN ISO / ISO 14119, IEC 60947-5-1, EN 60947-5-1
GS-ET-15, UL508, CSA C22.2 No.14, GB/T14048.5
Standards for Use
IEC 60204-1/ EN 60204-1
Interlocking device Type
Type 2 Interlocking device
/ the level of coded
/ low level coded actuator (EN ISO / ISO 14119)
Applicable Directives
Low Voltage Directive, Machinery Directive,
RoHS Directive
Operating
Operating Temperature
-25 to +70°C (no freezing)
Condition
Operating Humidity
45 to 85%RH (no condensation)
Storage Temperature
-40 to +80°C (no freezing)
Pollution Degree
3 (Inside2)
Altitude
2000m maximum
Impulse withstand voltage ‹Uimp›
4kV
Rated Insulation voltage ‹Ui›
300V
Thermal Current ‹Ith›
2.5A
Contact Ratings
( Reference Values )
‹Ue, Ie›
Electric Shock Protection Class
Class II (IEC 61140)
Operating Frequency
1200 operations/hour
Operating Speed
0.05 to 1.0 m/s
B10d
2,000,000 (EN ISO 13849-1 Annex C Table C.1)
Mechanical Durability
1,000,000 operations minimum (GS-ET-15)
Electrical Durability
100,000 operations min. (AC-12 250V•1.5A)
1,000,000 operations min. (AC/DC 24 100mA)
(1,200 operations / hour)
Shock Resistance
Operating Extremes: 300m/s
Vibration Resistance
Operating Extremes: 5 to 55 Hz, half amplitude 0.5mm
Damage Limits: 30 Hz, half amplitude 1.5 mm
Direct Opening Travel
8 mm minimum
Direct Opening Force
60 N minimum
300 mΩ maximum
Contact Resistance
Degree of Protection
IP67 (IEC 60529)
Conditional short circuit current
50A (250V)
Short-Circuit Protective Device
250V AC,10A fast acting type fuse
Weight
Approx. 120g (at HS6B-03B01)
* Make sure that a fast acting fuse for short-circuit protection trips before overheating of the wires.
Ratings approved by safety agencies
(1) TÜV rating
(2) UL, c-UL rating
AC-15 240V/0.75A
C300 0.75A, 240V ac, Pilot Duty
DC-13 250V/0.27A
Q300 0.27A, 250V dc, Pilot Duty
DC-13 30V/2.3A
(4) KOSHA rating
AC-15 240V/0.75A
DC-13 250V/0.27A
* In order to verify if the product
you are interested in is certified
with the S mark, please check
the following section on our
website: "List of type numbers
certified with the S mark"
61:Straight(Mainly for sliding doors)
62:L-shaped(Mainly for hinged doors)
65:Horizontal / Vertical Adjustment(Note)
66:Horizontal / Vertical Adjustment(Note)
30V
- 
Resistive load(AC-12)
AC
Inductive load(AC-15)
Resistive load(DC-12)
2.5A
DC
Inductive load(DC-13)
2.3A
2
, Damage Limits: 1,000m/s
(Initial value, at cable length 1m)
*
(3) CCC rating
AC-15 240V/0.75A
DC-13 30V/2.3A
Interlock Switch
3
Mounting Examples
Install the interlock switch on the immovable machine or guard,
and install the actuator on the movable door. Do not install both
interlock switch and actuator on the movable door, otherwise
failure will occur.
Note : When inserting an actuator into the slot, make sure to
arrange the
on the right.
Minimum Radius of Hinged Door
When using the interlock switch for a hinged door, the minimum radius of the applica-
ble door is shown in the following figures.
When the center of the hinged door is
on the extension line of the actuator
mounting surface.
• When using L-shaped actuator (HS9Z-A62)
HS9Z-A62
Door
Hinge
• When using angle adjustable actuator (HS9Z-A65/HS9Z-A66)
• When using angle adjustable actuator (HS9Z-A65/HS9Z-A66)
(Horizontal Adjustment)
HS9Z-A65
HS9Z-A66
(Vertical Adjustment)
HS9Z-A65
HS9Z-A66
125V
250V
2.5A
1.5A
Note: The figures shown above are based on the condition that the actuator enters
1.5A
0.75A
and exits the actuator entry slot smoothly when the door is closed or opened.
1.1A
0.55A
Since there may be deviation or misalignment of the hinged door, make sure of
0.55A
0.27A
correct operation in the actual application before installation.
Actuator Mounting Reference Position
As shown below, the mounting reference position of the actuator inserted into the
interlock switch is: The actuator stop touches the interlock switch lightly.
Note: After mounting the actuator, remove the actuator stop from the interlock switch.
Interlock Switch
2
Actuator Stop
HS9Z-A61
Actuator
Actuator Mounting Tolerance
• Mounting tolerance of the actua-
tor is 1.0mm from the center of
the actuator to up, down, right,
and, left.
• Make sure the actuator can be
inserted into the entry slot without
any issue.
shapes in the same direction, as shown
When the center of the hinged door
is on the extension line of the contact
surface of actuator and interlock
switch.
Door
Hinge
Door Hinge
LABEL
Door Hinge
Door Hinge
LABEL
Door Hinge
Door Stop
Door Stop
±1.0mm
±1.0mm
2021.09
B-1905-1(2)
Door
Door
Hinge
Hinge
Door Hinge
LABEL
Door Hinge
Door Hinge
LABEL
Door Hinge
Interlock Switch
Actuator Stop
HS9Z-A65, A66
Actuator
Interlock Switch
Center
( 1 / 4 )

Advertisement

loading

Summary of Contents for IDEC HS6B Series

  • Page 1 INSTRUCTION SHEET - HS6B Series 2021.09 Interlock Switch B-1905-1(2) Mounting Examples Install the interlock switch on the immovable machine or guard, and install the actuator on the movable door. Do not install both INSTRUCTION SHEET interlock switch and actuator on the movable door, otherwise ※...
  • Page 2 • HS6B Series Safety Switches are Type 2 low-level coded interlocking devices (EN ISO / ISO 14119). The following system installation & mounting instructions are...
  • Page 3 INSTRUCTION SHEET - HS6B Series 2021.09 Interlock Switch B-1905-1(2) Wiring Contact Operation Contact Configuration and Operation Identification of terminal numbers • When wiring, the identification of terminal number on each contact is made by Type Contact Configuration Contact Operation colored wire.
  • Page 4 Dispose of HS6B Interlock Switch as an industrial waste. the door (33.8) 28.2 http://www.idec.com DECLARATION OF CONFORMITY We, IDEC CORPORATION declare under our sole responsibility that the product: When installed on the door (5) Description: Interlock Switch Model No: HS6B Applied Union harmonized legislation and references to the relevant harmonization standards used or references the other technical specifications in relation to which conformity is declared.