HS5E Miniature Interlock Switches with Solenoid
Standard - Solenoid Lock
Interlock Switch Status
Door Status
Circuit Diagram (HS5E-A7Y)
Door
Door Monitor
Lock Monitor
(Actuator inserted)
(Solenoid ON)
(+)
A2
HS5E-A7Y
Main Circuit:
11
12
41
Monitor Circuit:
23
24
Monitor Circuit:
53
HS5E-B7Y
Main Circuit:
11
12
41
Monitor Circuit:
23
24
Monitor Circuit:
51
HS5E-C7Y
Main Circuit:
11
12
41
Monitor Circuit:
21
22
Monitor Circuit:
53
HS5E-D7Y
Main Circuit:
11
12
41
Monitor Circuit:
21
22
Monitor Circuit:
51
HS5E-F7Y
Main Circuit:
11
12
41
Monitor Circuit:
21
22
Monitor Circuit:
31
32
HS5E-G7Y
Main Circuit:
11
12
41
Monitor Circuit:
21
22
33
34
Monitor Circuit:
HS5E-H7Y
Main Circuit:
11
12
41
Monitor Circuit:
51
Monitor Circuit:
61
HS5E-J7Y
Main Circuit:
11
12
41
Monitor Circuit:
51
Monitor Circuit:
63
Solenoid Power A1-A2 (all model)
The above contact confi guration shows the status when the actuator is inserted and locked.
Main Circuit: Connected to the control circuit of machine drive part, sending interlock signals of the protective door.
Monitor Circuit:
Sends monitoring signals of protective door open/closed status or protective door lock/unlock status.
Operation Chracteristics (reference)
Main Circuit
Monitor Circuit (door open, NO)
Monitor Circuit (door closed, NC)
Monitor Circuit (unlocked, NO)
Monitor Circuit (locked, NC)
712
Status 1
Door Closed
Machine ready to
operate
Solenoid energized
(+)
(–)
A2
A1
11
12
41
42
23
24
53
54
Closed (locked)
Main Circuit
ON (closed)
11−42
(–)
Monitor Circuit
A1
OFF (open)
(door open)
23-24
42
Monitor Circuit
OFF (open)
(unlocked)
54
53−54
Main Circuit
ON (closed)
11−42
Monitor Circuit
42
OFF (open)
(door open)
23−24
52
Monitor Circuit
ON (closed)
(locked)
51−52
Main Circuit
ON (closed)
11−42
Monitor Circuit
42
ON (closed)
(door closed)
21−22
54
Monitor Circuit
OFF (open)
(unlocked)
53−54
Main Circuit
ON (closed)
11−42
Monitor Circuit
42
ON (closed)
(door closed)
21−22
52
Monitor Circuit
ON (closed)
(locked)
51−52
Main Circuit
ON (closed)
11−42
42
Monitor Circuit
ON (closed)
(door closed)
21−22
Monitor Circuit
ON (closed)
(door closed)
31−32
Main Circuit
ON (closed)
11−42
42
Monitor Circuit
ON (closed)
(door closed)
21−22
Monitor Circuit
OFF (open)
(door open)
33−34
Main Circuit
ON (closed)
11−42
42
Monitor Circuit
52
ON (closed)
(locked)
62
51−52
Monitor Circuit
ON (closed)
(locked)
61−62
Main Circuit
ON (closed)
11−42
42
Monitor Circuit
52
ON (closed)
(locked)
64
51−52
Monitor Circuit
OFF (open)
(unlocked)
63−64
ON (energized)
0
(Actuator insertion position)
3.3 (Locked position)
5.3
6.9
26.4 (travel in mm)
Status 2
Status 3
Door Closed
Door Open
Machine cannot be
Machine cannot be
operated
operated
Solenoid de-energized
Solenoid de-energized
(+)
(–)
A2
A1
11
12
41
42
11
23
24
53
54
23
Closed (unlocked)
Open
OFF (open)
OFF (open)
OFF (open)
ON (closed)
ON (closed)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
OFF (open)
ON (closed)
ON (closed)
OFF (open)
OFF (open)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
OFF (open)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
OFF (open)
OFF (open)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
ON (closed)
OFF (de-energized) OFF (de-energized)
The operation characteristics shown in the chart above are
of the HS9Z-A51. For other actuators, add 1.3 mm.
Contacts ON (closed)
The operation characteristics show the contact status when
Contacts OFF (open)
the actuator enters the entry slot of an interlock switch.
Unlocked with Manual
Status 4
Unlocking Key
Door Open
Door Closed
Machine cannot be
Machine cannot be
operated
operated
Solenoid de-energized
Solenoid energized
energized
(+)
(–)
A2
A1
11
12
12
41
42
23
24
24
53
54
Open
Closed (unlocked)
OFF (open)
OFF (open)
ON (closed)
OFF (open)
ON (closed)
ON (closed)
OFF (open)
OFF (open)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
ON (closed)
ON (closed)
OFF (open)
OFF (open)
OFF (open).
ON (closed)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
OFF (open)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
ON (closed)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
OFF (open)
ON (closed)
ON (closed)
ON (energized)
OFF to ON
(Note 2)
(Note 1) (Note 2)
Note 1: Do not attempt manual unlocking when
the solenoid is energized.
Note 2: Do not energize the solenoid for a long
time while the door is open or when the
door is unlocked manually.
LOCK
UNLOCK
Manual Unlock Status
(+)
(–)
A2
A1
41
42
53
54