1
Type
HS5D-11ZRNM
Contact configration
11 : 1NO-1NC
02 : 2NC
12 : 1NO-2NC
03 : 3NC
Material of Head
Blank : Plastic
Z
: Metal
2
Specifications and Ratings
Applicable Standards
EN ISO / ISO14119
IEC60947-5-1, EN60947-5-1, GS-ET-15
UL508, CSA C22.2 No.14, GB14048.5
Standards for Use
IEC60204-1, EN60204-1
Interlocking device Type
Type 2 Interlocking device
/ the level of coded
/ low level coded actuator (EN ISO / ISO14119)
Applicable Directives
Low Voltage Directive, Machinery Directive
Operating Condition
Operating Temperature
Operating Humidity
Pullution Degree
Al itude
Impulse with voltage ‹Uimp›
4kV
Rated Insula ion voltage ‹Ui›
300V
Thermal Current ‹Ith›
10A
Contact Ra ings
‹Ue, Ie›
AC
DC
Class of Protection
Class II (IEC61140)
900 operations / hour
Operating Frequency
0.05 to 1.0 m/s
Operating Speed
B10d
2,000,000 (EN ISO 13849-1 Annex C Table C.1)
Mechanical Durability
1,000,000 operations minimum (GS-ET-15)
Electrical Durability
100,000 operations min. (AC-12 250V•6A)
1,000,000 operations min. (AC/DC 24V 100mA)
(900 operations / hour)
Shock Resistance
Damage Limits: 1000m/s
Vibration Resistance
Operating Extremes:10 to 55 Hz, half amplitude 0.5mm
Damage Limits: 30 Hz, half amplitude 1.5mm
Direct Opening Travel
10 mm minimum (HS9Z-A51)
Direct Opening Force
50 N minimum (HS9Z-A51)
Contact Resistance
50mΩ maximum (Initial value)
Degree of Protection
IP67 (IEC60529)
Conditional short circuit current
100A(250V)
Short-Circuit Protective Device
250V AC, 10A fast acting type fuse
Ratings approved by safety agencies
(1) TÜV rating / CCC rating / KOSHA rating
AC-15 250V, 3A
DC-13 30V, 4A
* In order to verify if the product
you are interested in is certified
with the S mark, please check
the following section on our
website: "List of type numbers
certified with the S mark"
Gland Port Size
Blank : G1 /2
M
: M20
P
: PG13.5
-30 to +70°C (no freezing)
45 to 85%RH (no condensation)
3 (Inside 2)
2000m maximum
30V
125V
Resistive load (AC12)
10A
10A
Induc ive load (AC15)
10A
5A
Resistive load (DC12)
8A
2.2A
Induc ive load (DC13)
4A
1.1A
2
(2) UL, c-UL rating
A300 3A, 250V ac, Pilot Duty
4A, 30V dc
Safety Switch
HS5D Head Removal Detection Function (Screw Terminal No.11-12)
Mechanical durability
Insulation resistance
Dielectric strength
3

Mounting Examples

• Install the interlock switch on the immovable machine or guard, and install the
actuator on the movable door. Do not install both interlock switch and actuator on
the movable door, otherwise the angle of insertion of the actuator to the safety switch
may become inappropriate, and failure will occur.
HS9Z-A52
Actuator
Changing the Mounting Directions of
the HS5D Head
• The head of HS5D can be mounted in four
directions by removing the four screws on
the corners of the HS5D head.
WARNING
Mounting Directions of the HS5D Head
• When replacing the HS5D head, make sure that no foreign object enters into the
safety switch.
250V
• Tighten the screws tightly, o herwise he safety switch may malfunction.
6A
• Don't remove the screws of head expect when the mouting directions of head is
3A
changed.
1.1A
• When tightening the screw in the head section with an electric screwdriver or
similar tool, temporarily tighten the first part of the screw by hand first, and then
0.6A
tighten with the electric screwdriver.
Mounting the HS5D Head
• Do not use the metal head for the HS5L with lock type. Be sure to use the plastic
head or metal head for the HS5D. Be sure to use the correct head.
Plastic Head
10 operations min.
100MΩ(Initial value)
1,000V 1minute(Initial value)
(Examples of Mounting on Sliding Doors)
Door
HS9Z-A51
Actuator
HS5D
Safety Switch
Door Stop
(Examples of Mounting on Hinged Doors)
Hinged
Door
HS5D
Safety Switch
When
Shipped
HS5D
Plastic,
Metal,
Color:
Metal,
Color Red
Color:Silver
Red
Color:Silver
Color:Black
Metal Head
Metal Head
2016.08
B-1902-1(0)
HS9Z-SH5
Actuator
Alternative Moun ing
Directions
HS5L
( 1 / 5 )

Advertisement

loading

Summary of Contents for IDEC HS5D-11

  • Page 1: Mounting Examples

    INSTRUCTION SHEET - HS5D Series 2016.08 Safety Switch B-1902-1(0) HS5D Head Removal Detection Function (Screw Terminal No.11-12) 10 operations min. Mechanical durability 100MΩ(Initial value) Insulation resistance 1,000V 1minute(Initial value) Dielectric strength INSTRUCTION SHEET ※ Original Instructions Mounting Examples Safety Switch HS5D Series •...
  • Page 2 INSTRUCTION SHEET - HS5D Series 2016.08 Safety Switch B-1902-1(0) Actuator Mounting Reference Position HS5D Head Removal Detection Function As shown below, the mounting reference position of the actuator inserted into the • The the NC contacts of the two main circuits (11-12, 21-22) are operated similarly by safety switch is: the actuator.
  • Page 3: Precautions For Operation

    26.4 (Travel: mm) Approx. Approx. Approx. • When opening the safety switch lid to wire, open the lid 1 only. HS5D-11 Main Circuit: 11-12 Contact Closed (See the figure on the right.) Never remove other screws, other- Contact Open wise the safety switch may be damaged.
  • Page 4 One of the example of the circuit ; Safety the circuit ; Safety relay module, HR1S-AF relay module, HR1S-AF series manufactured series manufactured by IDEC CORPORATION by IDEC CORPORATION HR1S-AF Safety relay module HR1S-AF Safety relay module Output Circuit Output Circuit S12 S21...
  • Page 5: Dimensions (Mm)

    * The actuator has movement flexibility to the directions shown in B . DECLARATION OF CONFORMITY Actuator stop We, IDEC CORPORATION 2-6-64, Nishimiyahara Yodogawa-ku,Osaka 532-0004, Japan declare (supplied with actuator) Washer under our sole responsibility that the product: (supplied with actuator) Description: Safety Switch 2-Φ10...

This manual is also suitable for:

Hs5d-02Hs5d-12Hs5d-03