Temperature measuring (Auto. range)
Range
Resolution
-20°C~+1000°C
0.1°C/°C
-4°F~+1832°F
0.1°F/°F
K type measuring sensor
Inward voltage protection: 60V DC or 24 V AC RMS.
Ambient temperature (secondary display):
Resolution: 1°C
Accuracy: +3°C
Diode test
Current
Resolution
0.3mA
1 mV
Opening voltage: 1.5V DC.
Overload protection: 500V DC or AC RMS.
Audible continuity test
Threshold for audible
signal
Test current
Overload protection
Safety warnings on the LCD screen
RS232
AUTO
DC
AC
7
Disconnect power
for 30 sec. max every 15 min.
6
F1
5
1. Primary LCD display: For displaying
measured values, units, symbols, decimal points.
2. Secondary LCD display: For displaying
ambient temperature
3. Sign indicating imcorrect positioning of the
measuring wires
4. F2 fuse error
5. F1 fuse error
6. Indicates the two proper connectors in
various measuring ranges.
7. "Disconnect Power" signals that the power
should be disconnected from the circuit when
measuring resistance, continuity, capacity, diode
and temperature.
Accuracy
±(3%)
+2°C/°F
Accuracy
±(10%) + 5d
< 30Ω
<0.3mA
500V DC or AC RMS.
HOLD
kMÙ
Hz%
nìF
mVA
1
°C°F
°
RPM
2
4
2
uHmHH
-
- - -
°C°F
°
RH%
+
-
RPM
2 4
Hz KHz dB
RH
%
F2
4
3
DC/AC or OHM/DIODE/CONTINUITY/
CAPACITY or TEMPERATURE °C/°F mode
selection button
Press this button to select between AC/DC
voltage measuring mode if the function switch
is in „V" position.
Press this button to select between AC/DC
current measuring mode if the function switch
is in „uA,mA,20A" position.
Press this button to select between Resistance/
Diode/Continuity/Capacity measurement
modes if the function switch is set to „Ω
(Resistance) /
(Diode) /
(capacity)" position.
Press this button to select between °C and °F is
the function switch is set to °C/°F position.
Frequency and Duty Cycle
Press this button to select between
Frequency(Hz) / Duty cycle (%) modes if the
function switch is in „Hz/%" position.
RANGE selection button
On the first use the automatic range selection
is enabled.
You can activate the manual range selection
with the press of this button. By pressing the
button the device switches into manual mode
and the RANGE sign appears.
If the highest measuring range is reached, with
a press of the button the device goes back to
the lowest range.
By holding the RANGE button down for more
than 1 seconds, the RANGE sign disappears
and the device goes back to automatic range
mode.
HOLD button
If you would like to keep the last measured
value for a longer time, press this button (the
HOLD sign will appear, and the value will
stay on the screen until the next press of the
button).
By rotating the function switch the held data
automatically disappears.
REL (RELATIVE ZERO) button
This button is used for various (relative) starting
values and for comparing these.
(continuity) /