afety inforMation
Follow the safety and usage instructions to
ensure the proper state and operation of the
device.
Correct operation is only guaranteed if the
measuring wires are intact. Do not use the
device if the measuring wires appear to be
defective. In case of damage replace them
immediately.
Never ground yourself when measuring
electricity. Do not touch any metal pipes,
objects or parts that might be grounded.
To ensure insulation from the ground, use
insulating dry clothes, rubber-sole shoes or
floor mats or other insulating materials.
Always disconnect the power source from the
circuit before modifying it (soldering parts,
etc.). Even weak currents might be dangerous.
Be careful when measuring above 60V DC or
30V AC! These voltages may cause electric
shock!
When using the measuring prope, make sure
that your fingers do not touch its metal parts
and are always behind the finger protector.
To protect yourself and the device never
exceed the maximal inward values. Exceeding
these values may damage the device and the
user may experience an electric shock while
measuring.
s
afety syMbols
Symbols used in the manual and on the device
WARNING: Check the referring pages
of the manual. Improper usage may
!
lead to damage to the device.
Dangerous voltage.
s
pecifications
Complies to the EN61010-1
Safety
(CATIII)
„Optically" insulated
PC-connector (arbitrary)
RS232
RS-232 cable, Windows®
95/98/2000/XP compatible
(for data transfer).
large (double) LCD screen,
Display
4 digits, backlight.
Polarity
automatic, (-) negative
display
polarity display
Overload
„OL" on the screen
display
If battery power is running
Low battery
low, a battery icon appears
power
on the screen
Sampling rate
2x / sec (nominal)
If you do not use the
Automatic
device for 30 minutes, it
power off
powers off automatically.
Operating
0°C - 50°C (32°F - 122°F) (<
temperature
70 % humidity)
Storage
20°C - 60°C (-4°F - 140°F) (<
temperature
80 % humidity)
9V battery
Power
(NEDA 1604, IEC 6F22)
Dimensions
197 x 88.4 x 41.2 mm
Weight
635g (with case)
DC voltage measuring (Auto.range)
Range
Resolution
400 mV
0.1mV
4V
1mV
40V
10mV
400V
100mV
1000V
Inward impedance: 50MΩ 400mV threshold; 8.2MΩ (other
threshold.
Maximal inward voltage.: 1000V DC voltage or 750V AC
voltage.
Accuracy
±(0.5% )+ 2d
±(1.2%) + 2d
1V
±(1.5%) + 2d

Advertisement