EN
User Manual
s
afety inforMation
Follow the safety and usage instructions to
•
ensure the proper state and operation of the
device.
Correct operation is only guaranteed if the
•
measuring wires are intact. Do not use the
device if the measuring wires appear to be
defective. In case of damage replace them
immediately.
Never ground yourself when measuring
•
electricity. Do not touch any metal pipes,
objects or parts that might be grounded.
To ensure insulation from the ground, use
insulating dry clothes, rubber-sole shoes or
floor mats or other insulating materials.
Always disconnect the power source from the
•
circuit before modifying it (soldering parts,
etc.). Even weak currents might be dangerous.
Be careful when measuring above 60V DC or
•
30V AC! These voltages may cause electric
shock!
When using the measuring prope, make sure
•
that your fingers do not touch its metal parts
and are always behind the finger protector.
To protect yourself and the device never
•
exceed the maximal inward values. Exceeding
these values may damage the device and the
user may experience an electric shock while
measuring.
s
afety syMbols
Symbols used in the manual and on the device
WARNING: Check the referring pages
of the manual. Improper usage may
!
lead to damage to the device.
Dangerous voltage.
s
pecifications
Complies to the EN61010-1
Safety
(CATIII)
„Optically" insulated
PC-connector (arbitrary)
RS232
RS-232 cable, Windows®
95/98/2000/XP compatible
(for data transfer).
large (double) LCD screen,
Display
4 digits, backlight.
Polarity
automatic, (-) negative
display
polarity display
Overload
„OL" on the screen
display
If battery power is running
Low battery
low, a battery icon appears
power
on the screen
Sampling rate
2x / sec (nominal)
If you do not use the
Automatic
device for 30 minutes, it
power off
powers off automatically.
Operating
0°C - 50°C (32°F - 122°F) (<
temperature
70 % humidity)
Storage
20°C - 60°C (-4°F - 140°F) (<
temperature
80 % humidity)
9V battery
Power
(NEDA 1604, IEC 6F22)
Dimensions
197 x 88.4 x 41.2 mm
Weight
635g (with case)
DC voltage measuring (Auto.range)
Range
Resolution
400 mV
0.1mV
4V
1mV
40V
10mV
400V
100mV
1000V
Inward impedance: 50MΩ 400mV threshold; 8.2MΩ (other
threshold.
Maximal inward voltage.: 1000V DC voltage or 750V AC
voltage.
Accuracy
±(0.5% )+ 2d
±(1.2%) + 2d
1V
±(1.5%) + 2d