9 Installation in piping
9.3 Installation with inserts for welding
1. Carry out preparations for installation (see chapter "Pre-
paring for installation").
2. Adhere to good welding practices!
2
4
3. Unscrew the union nut 1 from the ball valve body 2.
4. Reinsert the gasket 3 if necessary.
2
4
5. Push the union nut 1 over the piping 5.
6. Push the piping 5 into the insert 4.
7. Weld the piping 5 to the insert 4 with a suitable welding
method and appropriate welding parameters and allow to
cool down.
8. Screw the union nut 1 to the ball valve body 2 again.
9. Connect the other connections of the ball valve body 2
with the piping 5 in the same manner.
GEMÜ 723
3
4
5
1
1
4
5
3
9.4 Installation with screw-type inserts
Thread sealant
▶ The thread sealant is not included in the scope of deliv-
ery.
Only use appropriate thread sealant.
●
1. Keep thread sealant ready.
2. Carry out preparations for installation (see chapter "Pre-
paring for installation").
4
3. Unscrew the union nut 1 from the ball valve body 2.
4. Reinsert the gasket 3 if necessary.
4
5. Push the union nut 1 over the piping 5.
6. Apply thread sealant on connection thread.
7. Screw the insert 4 into the piping 5.
8. Screw the union nut 1 to the ball valve body 2 again.
9. Connect the other connections of the ball valve body 2
with the piping 5 in the same manner.
28 / 64
NOTICE
2
3
4
2
3
4
www.gemu-group.com
5
1
1
5