The mobile lift is intended for use in the electromagnetic environment specified below. The customer or the user of the
mobile lift should assure that it is used in such an environment.
"Essential performance according to the manufacturer: The hoist shall not move unintentionally while being submitted to
disturbances."
Emissions test
RF emissions
CISPR 11
RF emissions
CISPR 11
Harmonic emissions
IEC 61000-3-2
Voltage fluctuations/ flicker emis-
sions
IEC 61000-3-3
The mobile lift is intended for use in the electromagnetic environment specified below. The customer or the user of the
mobile lift should assure that it is used in such an environment.
"Essential performance according to the manufacturer: The hoist shall not move unintentionally while being submitted to
disturbances."
Immunity test
Electrostatic
discharge (ESD)
IEC 61000-4-2
Electrical fast
transient / Burst
IEC 61000-4-4
Surge
IEC 61000-4-5
Voltage dips, short inter-
ruptions and voltage va-
riations on power supply
input lines
IEC 61000-4-11
Power frequency (50/60
Hz) magnetic field
IEC 61000-4-8
NOTE U
is the a.c. mains voltage prior to application of the test level.
T
7EN140108 Rev. 4 • 2020
Guidance and manufacturer's declaration – electromagnetic emissions
Compliance
Group 1
Class B
Complies
Complies
Guidance and manufacturer's declaration – electromagnetic immunity
IEC 60601 test level
+/- 8 kV contact
+/- 15 kV air
+/- 2 kV for power supply
lines
+/- 1 kV for input/output
lines
+/- 1 kV differential mode
+/- 2 kV common mode
0 % UT for 0,5 cycle, at 0, 45,
90, 135, 180, 225, 270 and
315 degrees
0 % UT for 1 cycle, at 0
degrees
70 % UT for 25 cycles at 50
Hz and 30 cycles at 60 Hz, at
0 degrees
0 % UT for 250 cycles at 50
Hz and 300 cycles at 60 Hz.
30 A/m

EMC Table

Electromagnetic environment - guidance
The mobile lift uses RF energy only for its internal function.
Therefore, its RF emissions are very low and are not likely to
cause any interference in nearby electronic equipment.
The mobile lift is suitable for use in all establishments inclu-
ding domestic establishments and those directly connected
to the public low-voltage power supply network that supplies
buildings used for domestic purposes.
Compliance level
+/- 8 kV contact
+/- 15 kV air
+/- 2 kV for power supply
lines
n/a. for input/output lines
+/- 1 kV differential mode
n/a. for common mode
0 % UT for 0,5 cycle, at 0,
45, 90, 135, 180, 225, 270
and 315 degrees
0 % UT for 1 cycle, at 0
degrees
70 % UT for 25 cycles at 50
Hz and 30 cycles at 60 Hz,
at 0 degrees
0 % UT for 250 cycles at 50
Hz and 300 cycles at 60 Hz.
Complies
7
Electromagnetic
environment - guidance
+/- 8 kV contact
+/- 15 kV air
Floors should be wood, concrete or
ceramic tile. If floors are covered
with synthetic material, the relative
humidity should be at least 30 %.
Mains power quality should be that
of a typical commercial or hospital
environment.
Mains power quality should be that
of a typical commercial or hospital
environment.
Mains power quality should be that
of a typical commercial or hospital
environment. If the user of the
[Equipment or System] requires
continued operation during power
mains interruptions, it is recom-
mended that the [Equipment or Sys-
tem] be powered from an uninter-
ruptible power supply or battery.
Power frequency magnetic fields
should be at levels characteristic of
a typical location in a typical com-
mercial or hospital environment