McQuay MWSC 010 Series Manual page 17

Split water source heat pump and cooling only unit
Table of Contents

Advertisement

Model: MCC 030M / MWSC 030B
Indoor
terminal block
2) Electrical parameter
Indoor unit
Model
Outdoor unit
Power source
Power input(W)
Running current(A)
area(mm²)
Power supply wire
Quantity
area(mm²)
Connecting cable
Quantity
ó The wiring must be fi rmly connected.
ó Electric wiring must not touch the refrigerant pipe, compressor and moving parts of the fan motor.
ó The wiring between indoor unit and outdoor unit must be fi xed by clamp.
All wiring between indoor unit and outdoor unit should be neoprene copper core, and section area of cable
ó
should be in accordance with above requirements.
The temperature sensor wire connecting outdoor unit with indoor unit
The malfunction wire connecting outdoor unit with indoor unit
220-240V
Power supply cable
E
N
220-240V/1Ph /50Hz
L
MCC 010M
MWSC 010B
Cooling
740
Cooling
3.5
Section
2.5
3
Section
2.5
3
Connecting cable
There must be a double pole
switch with minimum 3mm contact
gap in the installation circuit.
MCC 015M
MCC 020M
MWSC 015B
MWSC 020B
220V~/50Hz
1,700
5.5
2.5
3
2.5
3
Page 16
Outdoor
terminal block
MCC025M
MWSC025B
1,635
1,800
7.5
8.3
2.5
2.5
3
3
2.5
2.5
3
3
F
MCC 030M
MWSC 030B
2,350
11.1
2.5
3
2.5
1.5
2
2