Carrier X-POWER Series Service Manual page 30

Full dc inverter outdoor unit
Hide thumbs Also See for X-POWER Series:
Table of Contents

Advertisement

R410a DC Inverter 60Hz
Wiring diagram for 12~16HP
IC16
I
Blue
Black
Brown
Red
N
P
CN61
CN60
Brown
DC Filter Board B
Red
KM(A)
CN64
CN62
PTC-IN
CN63
N
P
L-1
L-2
Black
Red
Red
White
1L1
5L3
A1
L
N
XT1
KM(B)
Brown
Blue
A2
2T1
6T3
Blue
Red
Black
Red
Red
L-3
Brown
Black
Black
Blue
Red
BD-A
4
4
5
5
BD-B
3
2
1
3
2
1
Brown Brown Brown
Red
Red
Red
CN45
Filter Board A
L1' L2'
L3'
L1'L2'
L3'
L10
Filter Board B
L1
L2
L3
L1
L2
L3
Red
White
Blue
Red
White
Blue
CT2
Y e l l o w / G r e e n
CT1
White
Yellow/Green
Red
White
Blue
L1
L2
L3
XT2
220V 3~ 60Hz
28
IC17
I
N
CN62
Blue
CN61
CN64
N
DC Filter Board A
PTC-IN
CN60
Brown
Brown
P
CN63
P
Blue
Tsrq
T7C2
T7C1
Brown
P
Blue
FAN CONTROL PANEL B
FANB
N
CN1
CN4
CN24
CN21
CN20
CN8
CN11
CN10
H-YL1
L-YL1
ENC1
ENC2
SW1
COOL
CHECK
NUM _S POWER
ENC4
NET _ADDRESS
CN46
CN38
CN1
CN29
CN30
Yellow/Green
Blue
White
CN 6
CN 4
CN 5
K1 K2 E O A EX Y E P Q E
H1 H2 E
T oo u t d o o ru n i t s
T ok i l o w a t t h o u r
T oi n d o o ru n i t s
T oi n d o o ru n i t s
T oo u t d o o ru n i t s
m e t e r
c e n t r a lm o n i t o r
c e n t r a lm o n i t o r
c o m m u n i c a t i o nb u s
c o m m u n i c a t i o nb u s
P
FAN CONTROL PANEL A
FANA
N
CN1
CN4
T3
T4
H_PRO
L_PRO
N
+15V
Yellow
CN27
CN26
CN25
CN18
CN17
Inverter module A
SW2
DSP1
DSP2
Main control board
CN36
CN35
EXVA
EXVB
CN50
CN52
CN48
CN47
CN49
CN51
CN55
THE SETTING OF ENC2 IS NOT ALLOWED TO ALTER DISCRETIONARILY.
ST1
SV6
SV5
SV4
SV3
SV2
Carrier service manual
CODE
COMP( INV) 、
Inverter compressor
COMP( INV1)
DC fan
FANA、 FANB
ST1
Main 4-way valve
KM(A 、B)
Contactor
XT1 XT2
Terminal
L-PRO
Low pressure ON/OFF switch
H-PRO
High pressure ON/OFF switch
Elctronic expansion valve
EXVA、 EXVB
XS4-XS7
Middle terminal
XP4-XP7
Middle terminal
Condenser pipe Temp.sensor
T3
Outdoor Temp.sensor
T4
Discharge Temp.sensor
T7C1、 T7C2
of inverter compressor
L-YL1
Low pressure sensor
N
P
P
High pressure sensor
H-YL1
P
N
P
N
+15V
Reactor
L-1、 L-2 L-3
CT1、 CT2、
Current inductor
IC16、 IC17
Inverter module B
TRANS1、 TRANS2
Power transformer
3-phase bridge rectifier
U V W
U
V
W
SV1-SV6
Solenoid valve
HEAT 、
INV
Crankcase heater
HEAT
INV1
Red Black
Blue
Red Black Blue
DSP1 and DSP2 display content
E0
Outdoor unit COMM.Error
E2
COMM.Error with indoor unit
V
V
U
U
W
W
E4
T3 or T4 Temp.sensor error
E5
Voltage protecation
Discharge Temp.sensor error
COMP(INV)
COMP(INV1)
E7
E8
Outdoor unit address error
xH0
COMM.Error between DSP and main chip
Y e l l o w / G r e e n
Y e l l o w / G r e e n
H1
COMM.Error between 0537 and main chip
QTY.Of outdoor unit decreases error
H2
H3
QTY.Of outdoor unit increases error
xH4
3 times of P6 protection in 60 minutes
H5
3 times of P2 protection in 60 minutes
H6
3 times of P4 protection in 100 minutes
H7
QTY.Of indoor units decreases error
0
1
2
3
4
ENC2
H8
High pressure sensor error
CAPACITY SETTING
8HP
10HP
12HP
14HP
16HP
H9
3 times of P9 protection in 60 minutes
Auxiliary unit error ( y
yHd
0
1
2
3
1Hd stands for auxiliary unit1 error
ENC1
Main Unit Auxiliary
Auxiliary
Auxiliary
P1
High pressure protection
NETWORK SETTING
Unit 1
Unit 2
Unit 3
Low pressure protection
P2
xP3
Compressor current protection
P4
Discharge Temp.Protection
P5
High condenser Temp.Protection
xP6
Inverter module protection
P9
DC fan protection
PL
The Temp.of inverter module protection
C7
3 times of PL protection in 100 minutes
SV1
dF
Defrosting
d0
Oil returning
202095190945
Note:x reprsents for a system,1-A system,2-B system
Specification & Performance
NAME
=1,2,3.e.g,

Hide quick links:

Advertisement

Table of Contents
loading