Download Print this page

Graco Dura-Flo 2400 Instructions-Parts List Manual page 9

Stainless steel
Hide thumbs Also See for Dura-Flo 2400:

Advertisement

System Accessories
WARNING
A bleed-type master air valve (E) and a fluid drain
valve (M) are required in your system. These
accessories help reduce the risk of serious injury,
including fluid injection and splashing of fluid in the
eyes or on the skin, and injury from moving parts if
you are adjusting or repairing the pump.
The bleed-type master air valve relieves air trapped
between this valve and the pump after the air is
shut off. Trapped air can cause the pump to cycle
unexpectedly. Locate the valve close to the pump.
The fluid drain valve assists in relieving fluid pres-
sure in the displacement pump, hose, and gun.
Triggering the gun to relieve pressure may not be
sufficient.
Air and Fluid Hoses
Be sure all air hoses (H) and fluid hoses (N and P) are
properly sized and pressure-rated for your system.
Use only electrically conductive hoses. Fluid hoses
must have spring guards on both ends. Use a whip
hose (P) and a swivel (R) between the main fluid hose
(N) and the gun/valve (S) for easier gun/valve move-
ment.
Mounting Accessories
WARNING
For Model 222943 Premier Pumps, do not lift the
pump by the lift ring when the total weight exceeds
550 lb (250 kg).
Mount the pump (A) to suit the type of installation
planned. Fig. 3 illustrates a wall-mounted system.
Pump dimensions and the mounting hole layout are
shown on pages 44 and 45.
If you are using an elevator or a cart, refer to the
separate manuals supplied with those components for
installation and operation instructions.
Air Line Accessories
Install the following accessories in the order shown in
Fig. 3, using adapters as necessary:
D An air line lubricator (D) provides automatic air
motor lubrication.
Installation
(AIR-POWERED PUMPS)
D A bleed-type master air valve (E) is required in
your system to relieve air trapped between it and
the air motor when the valve is closed (see the
WARNING at left). Be sure the bleed valve is easily
accessible from the pump, and is located down-
stream from the air regulator.
D An air regulator (F) controls pump speed and
outlet pressure by adjusting the air pressure to the
pump. Locate the regulator close to the pump, but
upstream from the bleed-type master air valve.
D A pump runaway valve (C) senses when the
pump is running too fast and automatically shuts off
the air to the motor. A pump which runs too fast can
be seriously damaged.
D An air manifold (G) has a swivel air inlet. It
mounts to a wall bracket, and provides ports for
connecting lines to air-powered accessories.
D An air line filter (J) removes harmful dirt and
moisture from the compressed air supply.
D A second bleed-type air valve (K) isolates the air
line accessories for servicing. Locate upstream
from all other air line accessories.
Fluid Line Accessories
Install the following accessories in the positions shown
in Fig. 3, using adapters as necessary:
D A fluid filter (L) with a 60 mesh (250 micron)
stainless steel element, to filter particles from the
fluid as it leaves the pump. It includes a fluid drain
valve (M), which is required in your system to
relieve fluid pressure in the hose and gun (see the
WARNING at left).
D A gun or valve (S) dispenses the fluid. The gun
shown in Fig. 3 is an airless spray gun for light to
medium viscosity fluids.
D A gun swivel (R) allows for easier gun movement.
D A suction kit (T) allows the pump to draw fluid
from a 200 liter (55 gallon) drum.
308152
9

Advertisement

loading