Technical Data (Viscount Pump)
To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow
(lpm/gpm) and operating hydraulic pressure (psi/MPa/bar):
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet
pressure curve (black). Follow left to scale to read fluid outlet
pressure.
Fluid Outlet Pressure
psi
MPa, bar
13
2000
14, 140
A
1600
B
11.2, 112
1200
8.4, 84
800
C
5.6, 56
400
2.8, 28
0
0
2
gpm
liters/minute
7.6
Performance Charts: Viscount Pump
A
10.5 MPa, 105 bar (1500 psi) hydraulic oil pressure
B
7.5 MPa, 74 bar (1050 psi) hydraulic pressure
C
4.2 MPa, 42 bar (600 psi) hydraulic pressure
Test Fluid: No. 10 Weight Oil
cycles per minute
26
39
52
4
6
8
15.2
22.8
30.4
38.0
To find Pump Hydraulic Oil Consumption (m#/min or scfm) at a
specific fluid flow (lpm/gpm) and hydraulic pressure (psi/MPa/bar):
1. Locate desired flow along bottom of chart.
2. Read vertical line up to intersection with selected hydraulic con-
sumption curve (dashes). Follow left to scale to read oil consump-
tion.
gpm
lpm
65
16
60.8
12
45.6
8
30.4
4
15.2
0
10
0
gpm
liters/minute
Hydraulic Oil Consumption
cycles per minute
13
26
39
Hydraulic Oil
Consumption
2
4
6
7.6
15.2
22.8
52
65
8
10
30.4
38.0
308152