Download Print this page

Graco Dura-Flo 2400 Instructions-Parts List Manual page 40

Stainless steel
Hide thumbs Also See for Dura-Flo 2400:

Advertisement

Technical Data (Premier Pump)
Be sure that all fluids and solvents used are chemically compatible with the
Wetted Parts listed below. Always read the manufacturer's literature before
using fluid or solvent in this pump.
Category
Ratio
Maximum fluid working pressure
Maximum air input pressure
Pump cycles per 3.8 liters (1 gal.)
Fluid flow at 60 cpm
Air motor piston effective area
Stroke length
Displacement pump effective area
Maximum pump operating
temperature
Air inlet size
Fluid inlet size
Fluid outlet size
Weight
Wetted parts
Wetted parts (LASD Pumps
249157, 249158, and 253843)
Air Motor
Premier
Air Motor
Premier
40
308152
WARNING
Data
34:1
23.0 MPa, 234 bar (3400 psi)
0.7 MPa, 7 bar (100 psi)
6.5
34.6 liters/min (9.2 gpm)
2
2
800 cm
(38.5 in.
)
120 mm (4.75 in.)
2
2
24 cm
(3.72 in.
)
82_ C (180_ F)
3/4 npsm(f)
2 in. npt(f)
1–1/2 in. npt(m) or M42 x 2.0 (Part No. 241648 only)
approx. 109 kg (240 lb)
304, 329 and 17–4 PH Grades of Stainless Steel; Tungsten Carbide; acetal, PTFE,
Ultra-High Molecular Weight Polyethylene, Carbon-Filled PTFE (Part No. 241648 only)
304, 329 and 17–4 PH Grades of Stainless Steel, Silicone Nitride, Leather, acetal, PTFE,
UHMWPE, Tungsten Carbide
Sound Pressure Levels (dBa)
(measured at 1 meter from unit)
Input Air Pressures at 15 cycles per minute
0.28 MPa, 2.8 bar
0.48 MPa, 4.8 bar
(40 psi)
(70 psi)
82.5
82.4
Sound Power Levels (dBa)
(tested in accordance with ISO 9614–2)
Input Air Pressures at 15 cycles per minute
0.28 MPa, 2.8 bar
0.48 MPa, 4.8 bar
(40 psi)
(70 psi)
90.6
90.6
0.63 MPa, 6.3 bar
0.7 MPa, 7 bar
(90 psi)
(100 psi)
83.2
83.0
0.63 MPa, 6.3 bar
0.7 MPa, 7 bar
(90 psi)
(100 psi)
93.0
95.9

Advertisement

loading