Technical Data (Viscount Pump)
Be sure that all fluids and solvents used are chemically compatible with the
Wetted Parts listed below. Always read the manufacturer's literature before
using fluid or solvent in this pump.
Category
Maximum fluid working pressure
Maximum oil input pressure
Pump cycles per 3.8 liters (1 gal.)
Fluid flow at 60 cpm
Hydraulic motor piston effective area
Stroke length
Displacement pump effective area
Maximum pump operating
temperature
Hydraulic oil supply size
Hydraulic oil return size
Fluid inlet size
Fluid outlet size
Weight
Wetted parts
42
308152
WARNING
Data
14.0 MPa, 138 bar (2000 psi)
10.0 MPa, 103 bar (1500 psi)
6.5
34.9 liters/min (9.2 gpm)
2
2
31.6 cm
(4.9 in.
)
120 mm (4.75 in.)
2
2
24 cm
(3.72 in.
)
65.5_ C (150_ F)
3/4 npsm(f)
1 in. npt
2 in. npt(f)
1–1/2 in. npt(m)
approx. 89 kg (196 lb)
304, 329 and 17–4 PH Grades of Stainless Steel; Tungsten Carbide; acetal, PTFE,
Ultra-High Molecular Weight Polyethylene