Stainless steel
Hide thumbs Also See for Dura-Flo 2400:

Advertisement

Technical Data (King Pumps)
Be sure that all fluids and solvents used are chemically compatible with the
Wetted Parts listed below. Always read the manufacturer's literature before
using fluid or solvent in this pump.
Category
Ratio
Maximum fluid working pressure
Maximum air input pressure
Pump cycles per 3.8 liters (1 gal.)
Fluid flow at 50 cpm
Air motor piston effective area
Stroke length
Displacement pump effective area
Maximum pump operating
temperature
Air inlet size
Fluid inlet size
Fluid outlet size
Weight
Wetted parts
Air Motor
King
Quiet King
Air Motor
King
Quiet King
38
308152
WARNING
Data
20:1
13.8 MPa, 138 bar (2000 psi)
0.7 MPa, 7 bar (100 psi)
6.5
46 liters/min (12 gpm)
2
2
506 cm
(78.5 in.
)
120 mm (4.75 in.)
2
2
24 cm
(3.72 in.
)
82_ C (180_ F)
3/4 npsm(f)
2 in. npt(f)
1–1/2 in. npt(m)
approx. 69 kg (162 lb)
304, 329 and 17–4 PH Grades of Stainless Steel; Tungsten Carbide; acetal, PTFE,
Ultra-High Molecular Weight Polyethylene
Sound Pressure Levels (dBa)
(measured at 1 meter from unit)
Input Air Pressures at 15 cycles per minute
0.28 MPa, 2.8 bar
(40 psi)
78.8
77.9
Sound Power Levels (dBa)
(tested in accordance with ISO 9614–2)
Input Air Pressures at 15 cycles per minute
0.28 MPa, 2.8 bar
(40 psi)
86.5
85.2
0.48 MPa, 4.8 bar
(70 psi)
82.7
79.2
0.48 MPa, 4.8 bar
(70 psi)
88.8
86.6
0.63 MPa, 6.3 bar
(90 psi)
90.5
87.5
0.63 MPa, 6.3 bar
(90 psi)
97.7
95.2

Advertisement