Download Print this page

Graco Dura-Flo 2400 Instructions-Parts List Manual page 39

Stainless steel
Hide thumbs Also See for Dura-Flo 2400:

Advertisement

Technical Data (King Pumps)
To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow
(lpm/gpm) and operating air pressure (psi/MPa/bar):
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet
pressure curve (black). Follow left to scale to read fluid outlet
pressure.
Fluid Outlet Pressure
psi
cycles per minute
MPa, bar
13
1800
12.6, 126
A
1500
10.5, 105
B
1200
8.4, 84
900
6.3, 63
C
600
4.2, 42
300
2.1, 21
0
0
2
gpm
liters/minute
7.6
To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow
(lpm/gpm) and operating air pressure (psi/MPa/bar):
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet
pressure curve (black). Follow left to scale to read fluid outlet
pressure.
Fluid Outlet Pressure
psi
cycles per minute
MPa, bar
13
1800
12.6, 126
A
1500
10.5, 105
B
1200
8.4, 84
900
6.3, 63
C
600
4.2, 42
300
2.1, 21
0
0
2
gpm
liters/minute
7.6
Performance Charts: Standard King Pumps
A
0.6 MPa, 6.3 bar (90 psi) air pressure
B
0.5 MPa, 4.9 bar (70 psi) air pressure
C
0.3 MPa, 2.8 bar (40 psi) air pressure
Test Fluid: No. 10 Weight Oil
26
39
52
65
4
6
8
10
15.2
22.8
30.4
38.0
Performance Charts: Quiet King Pumps
A
0.6 MPa, 6.3 bar (90 psi) air pressure
B
0.5 MPa, 4.9 bar (70 psi) air pressure
C
0.3 MPa, 2.8 bar (40 psi) air pressure
Test Fluid: No. 10 Weight Oil
26
39
52
65
4
6
8
10
15.2
22.8
30.4
38.0
To find Pump Air Consumption (m#/min or scfm) at a specific fluid
flow (lpm/gpm) and air pressure (psi/MPa/bar):
1. Locate desired flow along bottom of chart.
2. Read vertical line up to intersection with selected air consumption
curve (dashes). Follow left to scale to read air consumption.
Air Consumption
scfm
cycles per minute
m#/min
13
225
6.30
180
5.04
135
3.78
90
2.52
45
1.26
0
0
2
gpm
liters/minute
7.6
To find Pump Air Consumption (m#/min or scfm) at a specific fluid
flow (lpm/gpm) and air pressure (psi/MPa/bar):
1. Locate desired flow along bottom of chart.
2. Read vertical line up to intersection with selected air consumption
curve (dashes). Follow left to scale to read air consumption.
Air Consumption
scfm
cycles per minute
m#/min
13
225
6.30
180
5.04
135
3.78
90
2.52
45
1.26
0
0
2
gpm
liters/minute
7.6
26
39
52
65
A
B
C
4
6
8
10
15.2
22.8
30.4
38.0
26
39
52
65
A
B
C
4
6
8
10
15.2
22.8
30.4
38.0
308152
39

Advertisement

loading