Technical Data (Premier Pump)
To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow
(lpm/gpm) and operating air pressure (psi/MPa/bar):
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet
pressure curve (black). Follow left to scale to read fluid outlet
pressure.
Fluid Outlet Pressure
psi
cycles per minute
MPa, bar
13
3500
24.5, 245
3000
A
21, 210
2500
17.5, 175
B
2000
14, 140
1500
10.5, 105
C
1000
7, 70
500
3.5, 35
0
0
2
gpm
liters/minute
7.6
Performance Charts: Premier Pumps
A
0.7 MPa, 7 bar (100 psi) air pressure
B
0.5 MPa, 4.9 bar (70 psi) air pressure
C
0.3 MPa, 2.8 bar (40 psi) air pressure
Test Fluid: No. 10 Weight Oil
26
39
52
65
4
6
8
10
15.2
22.8
30.4
38.0
To find Pump Air Consumption (m#/min or scfm) at a specific fluid
flow (lpm/gpm) and air pressure (psi/MPa/bar):
1. Locate desired flow along bottom of chart.
2. Read vertical line up to intersection with selected air consumption
curve (dashes). Follow left to scale to read air consumption.
Air Consumption
scfm
cycles per minute
m#/min
13
300
3.36
250
2.80
200
2.24
150
1.68
100
1.12
50
0.56
0
0
2
gpm
liters/minute
7.6
26
39
52
65
A
B
C
4
6
8
10
15.2
22.8
30.4
38.0
308152